[1]张鲁洁,姜严明,蔡春梅,等.调整Kappa角及光学切削直径对准分子激光原位角膜磨镶术后的影响[J].眼科新进展,2019,39(3):273-276.[doi:10.13389/j.cnki.rao.2019.0062]
 ZHANG Lu-Jie,JIANG Yan-Ming,CAI Chun-Mei,et al.Effects of adjusted optical zone ablation diameter with optimized Kappa angle on LASIK surgery[J].Recent Advances in Ophthalmology,2019,39(3):273-276.[doi:10.13389/j.cnki.rao.2019.0062]
点击复制

调整Kappa角及光学切削直径对准分子激光原位角膜磨镶术后的影响/HTML
分享到:

《眼科新进展》[ISSN:1003-5141/CN:41-1105/R]

卷:
39卷
期数:
2019年3期
页码:
273-276
栏目:
应用研究
出版日期:
2019-03-05

文章信息/Info

Title:
Effects of adjusted optical zone ablation diameter with optimized Kappa angle on LASIK surgery
作者:
张鲁洁姜严明蔡春梅范思均李晓琴魏琳高维平梁歌
100088 北京市,中国人民解放军火箭军特色医学中心眼科
Author(s):
ZHANG Lu-JieJIANG Yan-MingCAI Chun-MeiFAN Si-JunLI Xiao-QinWEI LinGAO Wei-PingLIANG Ge
Department of Ophthalmology,PLA Rocket Force Characteristic Medical Center,Beijing 100088,China
关键词:
切削直径Kappa角波前像差角膜厚度
Keywords:
ablation diameterKappa anglewavefront aberrationcorneal thickness
分类号:
R778
DOI:
10.13389/j.cnki.rao.2019.0062
文献标志码:
A
摘要:
目的 评价调整光学切削直径及Kappa角后对准分子激光原位角膜磨镶术(laser in situ keratomileusis,LASIK)后效果的影响。方法 选取2017年1月至12月在我院行LASIK手术的高度近视患者313例(626眼),根据切削直径分成两组,试验组157例314眼,切削直径设定为6.0 mm,对照组156例312眼,切削直径设定为6.5 mm。试验组患者激光切削前修正Kappa角,对照组不做修正。患者术前进行裸眼视力、主视眼确定、验光、眼压、暗室下瞳孔直径、泪液分泌试验、裂隙灯、散瞳验光、眼底检查、pentacam测量角膜厚度、角膜地形图测量角膜前后表面及Kappa角等检查。术后1 d、1周、1个月随访,并检查裸眼视力、角膜厚度、波前像差及夜间视力、光晕、眩光等情况。比较两组患者角膜厚度变化、手术所用时间以及两组患者术后的高阶像差的差异。结果 试验组与对照组患者年龄分别为18~44(24.19±5.33)岁、18~42(25.08±4.91)岁,屈光度分别为(-7.47±1.04)D、(-7.61±1.12)D。两组年龄、屈光度比较差异均无统计学意义(均为P>0.05)。试验组与对照组患者术前Kappa角分别为,X轴:(210±40)μm、(200±30)μm,Y轴:(190±30)μm、(220±40)μm,差异无统计学意义(P=0.210)。两组手术前后的角膜厚度及术后角膜基质床的厚度差异均无统计学意义(均为P>0.05)。试验组与对照组的手术时间分别为(15.56±1.89)s和(20.83±3.03)s,差异有统计学意义(P=0.000)。试验组的总高阶像差和垂直慧差的变化均明显低于对照组(均为 P<0.01),但两组间的水平慧差差异无统计学意义(P>0.05),对照组的球差低于试验组(P<0.01)。结论 LASIK手术中科学合理地调整Kappa角可有助于提高患者术后的视觉质量。
Abstract:
Objective To evaluate the effect of adjusting the optical ablation diameter and Kappa angle on the outcome of LASIK.Methods A total of 313 patients (626 eyes) with high myopia who underwent LASIK in our hospital from January 2017 to December 2017 were enrolled,and according to ablation diameter,the patients were divided into two groups:experimental group (157 patients,314 eyes) received LASIK with a narrowedoptical zone of 6.0 mm,and control group (156 patients,312 eyes) received a routine LASIK with an optical zone of 6.5 mm.Kappa angle was corrected before laser cutting in the experimental group,which was not performed in the control group.Uncorrected visual acuity,determination of dominant eye,optometry,intraocular pressure,diameter of pupil under dark chamber,tear secretion test,slit lamp,mydriasis optometry,fundus examination,pentacam measurement of corneal thickness and corneal topography were performed before operation.The uncorrected visual acuity,corneal thickness,wavefront aberration,night visual acuity,halo and glare were examined at 1 day,1 week and 1 month after operation.The changes of corneal thickness,the time of operation and the difference in higher-order aberrations between the two groups were compared.Results The patients in the experimental group and the control group were 18-44 (24.19±5.33) years old,18-42 (25.08±4.91) years old,respectively,and the average diopter equivalent spherical mirror was (-7.47±1.04)D,(-7.61±1.12)D,respectively.There was no statistically significant difference in age and diopter between the two groups (both P>0.05).The Kappa angles of the experimental group and control group were (210±40)μm,and (200±30)μm at X-axis,(190±30)μm and (220±40)μm at Y-axis,respectively,with no statistical difference (P=0.210).There was no significant difference in corneal thickness and thickness of the postoperative corneal stromal bed between the two groups (all P>0.05).However,the time spent on surgery of the experimental group [(15.56±1.89)s] and the control group [(20.83±3.03)s] was statistically significant (P=0.000).The total high-order aberration and vertical coma of the experimental group were significantly lower than those of the control group (both P<0.01),but there was no significant difference in the horizontal coma between the two groups(P>0.05).The spherical aberration of the control group was lower than that of the experimental group (P<0.01).Conclusion Reasonable corrected Kappa angle in LASIK surgery can be adopted to benefit patients’ visual quality.

参考文献/References:

[1] PARK C Y,OH S Y,CHUCK R S.Measurement of angle kappa and centration in refractive surgery[J].Curr Opin Ophthalmol,2012,23(4):269-275.
[2] MOSHIRFAR M,HOGGON R N,MUTHAPPAN V.Angle Kappa and its importance in refractive surgery[J].Oman J Ophthalmol,2013,6(3):151-158.
[3] BASMAK H,SAHIN A,YILDIRIM N,SARICICEK T,YURDAKUL S.The angle kappa in strabismic individuals[J].Strabismus,2007,15(4):193-196.
[4] YUE H Y,ZHANG L,GAO Q Y,CHEN Y L,ZHANG B H.Clinical study of angle kappa characteristic after strabotomy[J].Chin J Ocul Traum Occupat Eye Dis,2013,35(8):583-585.
岳红云,张丽,高清垚,陈亚琼,张百红.斜视手术对kappa角影响及临床意义[J].中华眼外伤职业眼病杂志,2013,35(8):583-585.
[5] KANELLOPOULOS A J.Topography-guided hyperopic and hyperopic astigmatism femtosecond laser-assisted LASIK:long-term experience with the 400 Hz eye-Q excimer platform[J].Clin Ophthalmol,2012,6:895-901.
[6] NEPOMUCENO R L,BOXER B S,WACHLER,KIM J M,SCRUGGS R,SATO M.Laser in situ keratomileusis for hyperopia with the LADAR Vision 4000 with centration on the coaxially sighted corneal light reflex[J].J Cataract Refract Surg,2004,30(6):1281-1286.
[7] CHAN C C,BOXER WACHLER B S.Centration analysis of ablation over the coaxial corneal light reflex for hyperopic LASIK[J].Refract Surg,2006,22(5):467-471.
[8] QI H,JIANG J J,JIANG Y M,WANG L Q,HUANG Y F.Kappa angles in different positions in patients with myopia during LASIK[J].Int J Ophthalmol,2016,9(4):585-589.
[9] MIERDEL P,KAEMMERER M,MROCHEN M,KRINKE H E,SELLER T.Ocular optical aberrometer for clinical use[J].Biomed Opt,2001,6(2):200-204.
[10] McALINDEN C,PESUDOVS K,MOORE J E.The development of an instrument to measure quality of vision:the quality of vision (QoV) questionnaire[J].Invest Ophthalmol Vis Sci,2010,51(11):5537-5545.
[11]  LIAN J C,LIAO H P,ZHANG L,YE S,DONG S Q.Changes in corneal thickness of Moria SBK,90 and 110 cutters during LASIK surgery[J].Chin Ophthalmic Res,2010,28(12):1158-1161.
廉井财,张士胜,叶盛,董世奇.MORIA SBK、90、110刀头切削角膜瓣的厚度变化及相关因素分析[J].眼科研究,2010,28(12):1158-1161.
[12] BUHREN J,YOON G,KENNER S,MACRAE S,HUXLIN K.The effect of optical zone decentration on lower-and higher-order aberrations after photor efractive keratectomy in a cat model[J].Invest Ophthalmol Vis Sci,2007,48(12):5806-5814.
[13] PORTER J,YOON G,MACRAE S,PAN G,TWIETMEYER T,COX I G,et al.Surgeon offsets and dynamic eye movements in laser refractive surgery[J].J Cataract Refract Surg,2005,31(11):2058-2066.
[14] ZHU L Y.Off-center cutting of excimer laser corneal refractive surgery[J].Chin Ophthalmic Res,2009,27(6):535-538.
朱良勇.准分子激光角膜屈光手术偏中心切削[J].眼科研究,2009,27(6):535-538.
[15] WANG Y,WANG Z J,GUO H Q,QUAN W.The influence of high-level aberration on the visual function of the human eye[J].Acta Optica Sinica,2005,25(11):1519-1525.
王杨,王肇圻,郭欢庆,全薇.人眼的高级像差对视功能的影响[J].光学学报,2005,25(11):1519-1525.
[16] FANG L H,WANG Z J,WANG W,LIU M.The influence of various aberrations of Zernike on the optical quality of human eyes[J].Acta Optica Sinica,2006,26(11):1721-1726.
方利华,王肇圻,王伟,刘铭.泽尼克各项像差对人眼光学质量的影响[J].光学学报,2006,26(11):1721-1726.
[17] QI H,JIANG J J,JIANG Y M,DU G P,HUANG Y F.Effect of adjusted Kappa angle of individual laser assisted in-situ keratomi leusis on high level aberration[J].Med Pharm J Chin PLA,2013,25(10):73-75.
齐惠,蒋晶晶,姜严明,杜改萍,黄一飞.修正Kappa角的个性化准分子激光原位角膜磨镶术对高阶像差的影响[J].解放军医药杂志,2013,25(10):73-75.
[18] SEILER T,KOUFALA K,RICHTER G.Iatrogenic keratectasia after laser in situ keratomileusis[J].Refract Surg,1998,14(3):312-317.
[19] LI Q,LI Y,LONG Q,AI F R,LUO Y,CHEN B J,et al.Comparison of wavefront aberrations between surface ablation and stromal ablation surgeries[J].Int Eye Sci,2011,11(1):51-55.
李俏,李莹,龙琴,艾凤荣,罗岩,陈秉钧,等.准分子激光角膜表层手术与基质层手术对眼波前像差的比较[J].国际眼科杂志,2011,11(1):51-55.
[20] MOK K H,LEE V W.Effect of optical zone ablation diameter on LASIK-induced higher order optical aberrations[J].Refract Surg,2005,21(2):141-143.
[21] KAUFMAN S C,MAITCHOUK D Y,CHIOU A G,BEUERMAN R W.Interface inflammation after laser in situ keratomileusis Sands of the Sahara syndrome[J].J Cataract Refract Surg,1998,24(12):1589-1593.
[22] LYLE W A,JIN G J.Interface fluid associated with diffuse lamellar keratitis and epithelial ingrowth after laser in situ keratomileusis[J].J Cataract Refract Surg,1999,25(7):1009-1012.

相似文献/References:

[1]赵武校 蓝方方 刘洪婷 李志超 甘露. 屈光参差性近视的Orbscan Ⅱz角膜地形图特性研究[J].眼科新进展,2014,34(1):051.
[2]肖畅,吴国玖,查旭,等.Kappa角在屈光手术中研究进展[J].眼科新进展,2018,38(2):193.[doi:10.13389/j.cnki.rao.2018.0044]
 XIAO Chang,WU Guo-Jiu,ZHA Xu,et al.Research progress of angle Kappa in refractive surgery[J].Recent Advances in Ophthalmology,2018,38(3):193.[doi:10.13389/j.cnki.rao.2018.0044]
[3]温凯,张红,孙靖,等.kappa角在人群中的分布:基于iTrace像差仪的研究[J].眼科新进展,2018,38(3):265.[doi:10.13389/j.cnki.rao.2018.0062]
 WEN Kai,ZHANG Hong,SUN Jing,et al.Distribution of kappa angle measured by iTrace in a population of China[J].Recent Advances in Ophthalmology,2018,38(3):265.[doi:10.13389/j.cnki.rao.2018.0062]
[4]樊保良,王静,邵雨双,等.Lenstar LS900测量仪与 iTrace视觉功能分析仪测量白内障患者术前Kappa角与Alpha角一致性研究[J].眼科新进展,2020,40(4):340.[doi:10.13389/j.cnki.rao.2020.0078]
 FAN Baoliang,WANG Jing,SHAO Yushuang,et al.Comparative study on consistency of Lenstar LS900 and iTrace for measuring Kappa angle and Alpha angle in cataract patients before surgery[J].Recent Advances in Ophthalmology,2020,40(3):340.[doi:10.13389/j.cnki.rao.2020.0078]
[5]贾寓洁,汝新宇,林淑华,等.不同Kappa角补偿的波前像差引导飞秒激光联合准分子激光原位角膜磨镶术对患者屈光度和视觉质量的影响[J].眼科新进展,2021,41(12):1133.[doi:10.13389/j.cnki.rao.2021.0237]
 JIA Yujie,RU Xinyu,LIN Shuhua,et al.Effect of wavefront aberration-guided femtosecond laser-assisted in situ keratomileusis with different angle Kappa adjustments on diopter and visual quality[J].Recent Advances in Ophthalmology,2021,41(3):1133.[doi:10.13389/j.cnki.rao.2021.0237]
[6]赵景华,贾寓洁,林淑华,等.近视患者优势眼与非优势眼的Kappa角、瞳孔大小及中心位置的动态变化[J].眼科新进展,2022,42(2):142.[doi:10.13389/j.cnki.rao.2022.0029]
 ZHAO Jinghua,JIA Yujie,LIN Shuhua,et al.Dynamic changes in the angle Kappa, pupil size, and center position among dominant and nondominant eyes in myopic patients[J].Recent Advances in Ophthalmology,2022,42(3):142.[doi:10.13389/j.cnki.rao.2022.0029]
[7]淦帆,秦伟国,刘慧,等.不同光照条件下近视患者Kappa角的特征及变化规律[J].眼科新进展,2023,43(1):057.[doi:10.13389/j.cnki.rao.2023.0012]
 GAN Fan,QIN Weiguo,LIU Hui,et al.Characteristics of angle Kappa in myopic people and changing rules under varying illuminations[J].Recent Advances in Ophthalmology,2023,43(3):057.[doi:10.13389/j.cnki.rao.2023.0012]
[8]康婷婷,尹连荣,刘沙沙,等.SMILE术中大Kappa角的调整对术后全眼高阶像差的影响[J].眼科新进展,2023,43(10):790.[doi:10.13389/j.cnki.rao.2023.0159]
 KANG Tingting,YIN Lianrong,LIU Shasha,et al.Effects of adjustment of large angle Kappa during small incision lenticule extraction on postoperative total higher-order aberrations[J].Recent Advances in Ophthalmology,2023,43(3):790.[doi:10.13389/j.cnki.rao.2023.0159]

更新日期/Last Update: 2019-03-15