[1]郭晓娜,陆惠,寇豆,等.OPD-Scan Ⅲ及IOL-Master 700测量白内障术前角膜曲率和水平角膜直径的比较[J].眼科新进展,2024,44(5):391-395.[doi:10.13389/j.cnki.rao.2024.0076]
 GUO Xiaona,LU Hui,KOU Dou,et al.Comparison of OPD-Scan III and IOL-Master 700 in measuring corneal curvature and horizontal corneal diameter before cataract surgery[J].Recent Advances in Ophthalmology,2024,44(5):391-395.[doi:10.13389/j.cnki.rao.2024.0076]
点击复制

OPD-Scan Ⅲ及IOL-Master 700测量白内障术前角膜曲率和水平角膜直径的比较/HTML
分享到:

《眼科新进展》[ISSN:1003-5141/CN:41-1105/R]

卷:
44卷
期数:
2024年5期
页码:
391-395
栏目:
应用研究
出版日期:
2024-04-30

文章信息/Info

Title:
Comparison of OPD-Scan III and IOL-Master 700 in measuring corneal curvature and horizontal corneal diameter before cataract surgery
作者:
郭晓娜陆惠寇豆于璐凌宇
100049 北京市,航天中心医院
Author(s):
GUO XiaonaLU HuiKOU DouYU LuLING Yu
Aerospace Center Hospital,Beijing 100049,China
关键词:
OPD-Scan ⅢIOL-Master 700角膜曲率角膜水平直径
Keywords:
OPD-Scan Ⅲ IOL-Master 700 corneal curvature white-to-white distance
分类号:
R776.1
DOI:
10.13389/j.cnki.rao.2024.0076
文献标志码:
A
摘要:
目的 比较OPD-Scan Ⅲ与IOL-Master 700在角膜曲率(平坦曲率K1与陡峭曲率K2)及水平角膜直径(WTW)测量上的差异性及一致性。
方法 选取2021年10月至2022年9月在航天中心医院眼科行白内障手术的患者268例328眼(右眼164例,左眼164例)。采用OPD-Scan Ⅲ及IOL-Master 700仪器分别检测患者左右眼的K1、K2以及WTW值并进行分析比较。采用配对t检验进行参数比较;Pearson相关分析检测参数间的相关性;Bland-Altman以及组内相关系数(ICC)分析确定两种仪器相关参数测量的一致性。
结果 在左右眼参数的测量中,OPD-ScanⅢ测得的K1及K2值均大于IOL-Master 700,WTW值均低于IOL-Master 700的测量值,差异均有统计学意义(均为P<0.001)。OPD-Scan Ⅲ在左右眼中测得的K1、K2及WTW值与IOL-Master 700所测得的对应值均呈正相关,差异均有统计学意义(均为P<0.001)。两种仪器K1、K2及WTW值在95%一致性界限外的比例均在5%以内,但95%界限内差值绝对值均接近或超过了1.0 D,存在较大的临床偏差。ICC分析证实两种仪器左右眼测量K1及K2值一致性均极好(ICC>0.90)。两种仪器测得的WTW差值与K2值均显著相关(均为P<0.05)。WTW正偏差范围外有5例(83.33%)样本IOL-Master 700测得的K2在47.03以上。
结论 OPD-Scan Ⅲ及IOL-Master 700在测量K1、K2及WTW上存在偏差,临床应用中不可互相替代。IOL-Master 700测得的WTW值大于OPD-Scan Ⅲ,当其测量的K2 ≥ 47.03时,所获得的WTW值参考价值可能有限。
Abstract:
Objective To compare the difference and consistency between OPD-Scan Ⅲ and IOL-Master 700 in the measurement of corneal curvature (flat keratometry, K1 and steep keratometry, K2) and horizontal corneal diameter (white-to-white (WTW) distance).
Methods Totally 268 patients with 328 eyes (164 right eyes and 164 left eyes) who underwent cataract surgery at the Department of Ophthalmology of the Aerospace Centre Hospital from October 2021 to September 2022 were selected for this study. The K1, K2, and WTW values of the sampled right or left eyes were measured and analyzed using OPD-Scan Ⅲ and IOL-Master 700, respectively. Parameter comparisons were performed through paired t-tests; correlations between parameters were detected through the Pearson correlation analysis; and the Bland-Altman method and intragroup correlation coefficient (ICC) analysis were employed to determine the consistency of parameter measurements between the two instruments.
Results The K1 and K2 values measured by OPD-Scan Ⅲ were greater than those measured by IOL-Master 700, while the WTW values were lower than those measured by IOL-Master 700, but the differences were statistically significant (all P<0.001). K1, K2, and WTW values measured by OPD-Scan Ⅲ were positively correlated with the corresponding values measured by IOL-Master 700, and the differences were statistically significant (all P<0.001). The proportions of K1, K2, and WTW values outside the 95% limits of agreement for both instruments were within 5%, but the absolute value of the difference in values within the 95% limits of agreement was close to or more than (1.0) D, indicating a sizeable clinical deviation. ICC analysis confirmed a good consistency between K1 and K2 values of the left and right eyes measured by the two instruments (ICC>0.90). The difference in WTW values measured by the two instruments was significantly correlated with K2 values (both P<0.05). There were 5 samples (83.33%) outside the positive deviation range of WTW values, of which K2 measured by IOL-Master 700 was above 47.03.
Conclusion The OPD-Scan III and IOL-Master 700 have been found to have measurement biases when assessing K1, K2 and WTW. In clinical practice, the two instruments cannot be interchanged as an alternative to each other. The WTW values measured by IOL-Master 700 are greater than those obtained by OPD-Scan Ⅲ; when K2≥47.03, the WTW values may not be reliably referrable.

参考文献/References:

[1] ANG M,GATINEL D,REINSTEIN D Z,MERTENS E,ALIDEL BARRIO J L,ALI J L.Refractive surgery beyond 2020[J].Eye,2021,35(2):362-382.
[2] LU L W,ROCHA-DE-LOSSADA C,RACHWANI-ANIL R,FLIKIER S,FLIKIER D.The role of posterior corneal power in 21st century biometry:a review[J].J Fr Ophtalmol,2021,44(7):1052-1058.
[3] OLESZKO A A,MAREK J J,MUZYKA-WO?NIAK M M.Horizontal and anterior chamber diameter for phakic intraocular lens sizing[J].Clin Exp Optom,2021,104(1):62-68.
[4] 王婷婷,王抒阳,张敏,秦鲁宁,林松.CASIA2、IOLMaster 700和Pentacam对白内障眼角膜屈光力及散光测量的比较[J].中华实验眼科杂志,2022,40(11):1055-1061.
WANG T T,WANG S Y,ZHANG M,QIN L N,LIN S.Comparison of corneal refractive power and astigmatism measured by CASIA2,IOLMaster 700 and Pentacam in cataract patients[J].Chin J Exp Ophthalmol,2022,40(11):1055-1061.
[5] CRUZ S,VALENZUELA F,STOPPEL J,MAUL E,GIBBONS A.Comparison of horizontal corneal diameter measurements using orbscan IIz,OPD scan III,and IOLMaster 700[J].Eye Contact Lens,2021,47(10):533-538.
[6] 陶露莎,董登昊,郎敏,陈爽,冯英,吴敏.CASIA2与IOL Master 700测量白内障患者角膜屈光力及散光的差异性和一致性[J].国际眼科杂志,2023,23(6):1017-1023.
TAO L S,DONG D H,LANG M,CHEN S,FENG Y,WU M.Difference and consistency of corneal refractive power and astigmatism in cataract patients measured by CASIA2 and IOL Master 700[J].Int Eye Sci,2023,23(6):1017-1023.
[7] EIBSCHITZ-TSIMHONI M,TSIMHONI O,ARCHER S M,DEL MONTE M A.Effect of axial length and keratometry measurement error on intraocular lens implant power prediction formulas in pediatric patients[J].J AAPOS,2008,12(2):173-176.
[8] XIA T,MARTINEZ C E,TSAI L M.Update on intraocular lens formulas and calculations[J].Asia Pac J Ophthalmol(Phila),2020,9(3):186-193.
[9] SRIVANNABOON S,CHIRAPAPAISAN C.Comparison of refractive outcomes using conventional keratometry or total keratometry for IOL power calculation in cataract surgery[J].Graefes Arch Clin Exp Ophthalmol,2019,257(12):2677-2682.
[10] 周桂梅,谭青青,廖萱,钱玖林,唐玉玲,杨丽,等.眼前段光学相干断层扫描仪CASIA2测量白内障患者角膜曲率和散光的重复性和再现性[J].眼科新进展,2021,41(5):466-469.
ZHOU G M,TAN Q Q,LIAO X,QIAN J L,TANG Y L,YANG L,et al.Repeatability and reproducibility of corneal curvature and astigmatism measured by optical coherence tomography CASIA2 in cataract patients[J].Rec Adv Ophthalmol,2021,41(5):466-469.
[11] LU W,LI Y,SAVINI G,SONG B,HU Q,WANG Q,et al.Comparison of anterior segment measurements obtained using a swept-source optical coherence tomography biometer and a Scheimpflug-Placido tomographer[J].J Cataract Refract Surg,2019,45(3):298-304.
[12] 马烈,李伟力,张涛.三种仪器测量水平角膜直径的差异及其与睫状沟直径的一致性研究[J].中华眼外伤职业眼病杂志,2022,44(11):863-867.
MA L,LI W L,ZHANG T.Difference of horizontal corneal diameter measured by three devices and consistency horizontal sulcus to sulcus diameter[J].Chin J Ocul Trauma Occup Eye Dis,2022,44(11):863-867.
[13] 杜亚茹,李学喜.四种不同仪器测量白内障患者术前角膜曲率和散光的比较[J].国际眼科杂志,2018,18(5):904-908.
DU Y R,LI X X .Comparison of corneal curvature and astigmatism measurements with four kinds of instruments before cataract surgery[J].Int Eye Sci,2018,18(5):904-908.
[14] SAYED K M,ALSAMMAN A H.Interchangeability between Pentacam and IOLMaster in phakic intraocular lens calculation[J].Eur J Ophthalmol,2015,25(3):202-207.
[15] PLAT J,HOA D,MURA F,BUSETTO T,SCHNEIDER C,PAYEROLS A,et al.Clinical and biometric determinants of actual lens position after cataract surgery[J].J Cataract Refract Surg,2017,43(2):195-200.
[16] GUBER I,BERGIN C,PERRITAZ S,MAJO F.Correcting interdevice bias of horizontal white-to-white and sulcus-to-sulcus measures used for implantable collamer lens sizing[J].Am J Ophthalmol,2016,161:116-125.e1.
[17] THEODOULIDOU S,ASPROUDIS I,KALOGEROPOULOS C,ATHANASIADIS A,ASPIOTIS M.Corneal diameter as a factor influencing corneal astigmatism after cataract surgery[J].Cornea,2016,35(1):132-136.
[18] HAN E S,KIM M.Evaluation of biometry and corneal astigmatism in cataract surgery patients in Northern United Arab Emirates[J].Int Ophthalmol,2019,39(12):2807-2813.
[19] BOYD B M,BAI J,BORGSTROM M,BELIN M W.Comparison of Chinese and North American tomographic parameters and the implications for refractive surgery screening[J].Asia Pac J Ophthalmol(Phila),2020,9(2):117-125.
[20] SALOUTI R,NOWROOZZADEH M H,TAJBAKHSH Z,BAGHERI M,GHOREYSHI M,AZIZZADEH M,et al.Agreement of corneal diameter measurements obtained by a swept-source biometer and a scheimpflug-based topographer[J].Cornea,2017,36(11):1373-1376.
[21] 李跃祖,李俊,张洁莹,梁刚.正常角膜生物力学参数与角膜直径的相关性分析[J].眼科新进展,2022,42(7):534-537.
LI Y Z,LI J,ZHANG J Y,LIANG G.Correlation between corneal biomechanical parameters and corneal diameter[J].Rec Adv Ophthalmol,2022,42(7):534-537.

备注/Memo

备注/Memo:
航天医疗健康科技集团有限公司医学科研项目(编号:2022YK28)
更新日期/Last Update: 2024-05-05