[1]刘志慧,陆强.SMILE术后患者早期角膜生物力学变化与角膜体积变化、角膜高阶像差变化之间的关系[J].眼科新进展,2024,44(1):048-51.[doi:10.13389/j.cnki.rao.2024.0009]
 LIU Zhihui,LU Qiang.Correlation of corneal biomechanical changes with corneal volume changes and high-order aberration changes in the early stage after small incision lenticule extraction[J].Recent Advances in Ophthalmology,2024,44(1):048-51.[doi:10.13389/j.cnki.rao.2024.0009]
点击复制

SMILE术后患者早期角膜生物力学变化与角膜体积变化、角膜高阶像差变化之间的关系/HTML
分享到:

《眼科新进展》[ISSN:1003-5141/CN:41-1105/R]

卷:
44卷
期数:
2024年1期
页码:
048-51
栏目:
应用研究
出版日期:
2024-01-05

文章信息/Info

Title:
Correlation of corneal biomechanical changes with corneal volume changes and high-order aberration changes in the early stage after small incision lenticule extraction
作者:
刘志慧陆强
528000 广东省佛山市,佛山市第二人民医院视光学中心
Author(s):
LIU ZhihuiLU Qiang
Department of Ophthalmology,the Second People’s Hospital of Foshan,Foshan 528000,Guangdong Province,China
关键词:
角膜生物力学参数角膜体积角膜高阶像差飞秒激光小切口角膜基质透镜取出术近视
Keywords:
corneal biomechanical parameters corneal volume high-order corneal aberration small incision lenticule extraction myopia
分类号:
R778
DOI:
10.13389/j.cnki.rao.2024.0009
文献标志码:
A
摘要:
目的 探讨飞秒激光小切口角膜基质透镜取出术(SMILE)术后患者早期角膜生物力学的变化,分析角膜生物力学变化与角膜体积变化、角膜高阶像差变化之间的关系。方法 选取 2021年1月至8月在佛山市第二人民医院视光学中心拟行SMILE的近视及近视散光患者72例(72眼)作为研究对象,取患者的右眼作为观测眼。术前和术后3个月分别应用新一代Corvis? ST测量患者角膜生物力学新型参数[非接触生物力学校正眼压(bIOP)、2 mm处变形幅度的比值(DA ratio)、综合半径(IR)、最薄点厚度/厚度变化率(ARTh;用来评估角膜的形态和质量)、第一次压平时角膜硬度参数(SP-A1)、Corvis生物力学指数(CBI)和应力和应变参数(SSI)];应用Pentacam测量患者角膜生物力学参数,包括:角膜体积(CV3 mm、CV5 mm、CV7 mm和CV10 mm);全角膜、角膜前表面、角膜后表面总均方根[RMS(Cornea、CF、CB)];全角膜、角膜前表面、角膜后表面高阶像差均方根[RMS HOA (Cornea、CF、CB)]。采用配对t检验或Wilcoxon符号秩检验分析各项参数的变化;采用偏最小二乘回归分析和Spearman相关性分析研究SMILE术后角膜生物力学新型参数变化量与角膜体积变化量、角膜高阶像差参数变化量之间的相关性。结果 术后3个月,患者角膜bIOP、ARTh、SP-A1和SSI较术前明显下降;DA ratio、IR和CBI较术前明显升高,差异均有统计学意义(均为P<0.05)。术后3个月,患者角膜CV3 mm、CV5 mm、CV7 mm和CV10 mm均较术前显著降低,差异均有统计学意义(均为P<0.05)。角膜体积变化量从小到大依次为 CV3 mm 、CV5 mm 、CV7 mm 、CV10 mm ,越往周边减少量增加。术后3个月,患者RMS(Cornea、CF、CB)、RMS HOA (Cornea、CF、CB) 均较术前显著增加,差异均有统计学意义(均为P<0.05);相对于角膜前表面高阶像差的变化,角膜后表面高阶像差的变化相对稳定。相关分析结果显示,△ARTh与△CV3 mm、△CV5 mm均呈正相关,与△CV10 mm呈负相关(均为P<0.05);△bIOP与△CV3 mm、△CV5 mm、△RMS HOA(CF)、△RMS HOA(Cornea)均呈负相关,与△CV10 mm呈正相关(均为P<0.05);△IR与△CV10 mm呈负相关(P<0.05);△SP-A1与△CV10 mm呈正相关(P<0.05);△CBI与△CV3 mm、△CV5 mm均呈负相关,与△CV10 mm、△RMS(CF)均呈正相关(均为P<0.05)。结论 SMILE术后患者早期角膜生物力学发生了一些变化,这些角膜生物力学变化与不同区域角膜体积变化、角膜高阶像差参数变化存在一定的相关性。
Abstract:
Objective To observe the corneal biomechanical changes of patients in the early stage after small incision lenticule extraction (SMILE), and to analyze the correlation between the corneal biomechanical changes and changes in corneal volumes and higher-order aberrations. Methods A total of 72 patients (72 eyes) with myopia or myopic astigmatism who were scheduled for SMILE in the Optometric Center of Second People’s Hospital of Foshan from January to August 2021 were included. The right eye was selected for observation. Before and 3 months after the SMILE, novel corneal biomechanical parameters, such as biomechanical intraocular pressure (bIOP), DA ratiomax (2 mm) (DA2 ratio), integrated radius (IR), Ambrósio’s relational thickness (for evaluation of the morphology and quality of the cornea, ARTh), stiffness parameter applanation 1 (SP-A1), Corvis biomechanical index (CBI) and stress-strain index (SSI), were measured by the new generation of Corvis? ST. The Pentacam anterior segment analysis system was used to measure corneal biomechanical parameters, including corneal volume (CV3 mm, CV5 mm, CV7 mm and CV10 mm); total root mean square of whole cornea, anterior and posterior corneal surface [RMS (Cornea, CF, CB)]; root mean square of high-order aberrations of total cornea, anterior and posterior corneal surface [RMS HOA (Cornea, CF, CB)]. Paired t-test or Wilcoxon singed-rank test was used to compare the changes in parameters before and after SMILE. Spearman correlation analysis and partial least squares regression were used to study the correlation between changes in novel corneal biomechanical parameters with corneal volume changes and high-order corneal aberration changes after the SMILE.Results Three months after SMILE, the bIOP, ARTh, SP-A1 and SSI decreased significantly, while the DA2 ratio, IR and CBI increased significantly (all P<0.05). Three months after SMILE, CV3 mm, CV5 mm, CV7 mm and CV10 mm decreased significantly (all P<0.05). The corneal volume changes from small to large were CV3 mm, CV5 mm, CV7 mm and CV10 mm, with a maximum decrease in the outmost periphery. The RMS (Cornea, CF, CB) and RMS HOA (Cornea, CF, CB) increased significantly (all P<0.05); compared with the changes in high-order aberration on the anterior corneal surface, the changes in higher-order aberration on the posterior corneal surface were relatively stable. Correlation analysis shows that △ARTh was positively correlated with △CV3 mm and △CV5 mm, and negatively correlated with △CV10 mm (all P<0.05); △bIOP was negatively correlated with △CV3 mm, △CV5 mm, △RMS HOA (CF) and △RMS HOA (Cornea) and positively correlated with △CV10 mm (all P<0.05); △IR was negatively correlated with △CV10 mm (P<0.05); △SP-A1 was positively correlated with △CV10 mm (P<0.05); △CBI was negatively correlated with △CV3 mm and △CV5 mm, and positively correlated with △CV10 mm and △RMS(CF)(all P<0.05). Conclusion The changes in corneal biomechanical parameters occur in the early stage after SMILE, with a certain correlation with the corneal volume changes in different regions and high-order corneal aberration changes.

参考文献/References:

[1] SEKUNDO W,KUNERT K S,BLUM M.Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism:results of a 6 month prospective study[J].Brit J Ophthalmol,,2011,95(3):335-339.
[2] NMETH G,HASSAN Z,MDIS L ,SZALAI E,KATONA K,BERTA A.Comparison of anterior chamber depth measurements conducted with Pentacam HR? and IOLMaster?[J].Ophthalmic Surg Lasers Imaging,2011,42(2):144-147.
[3] OZKAN H H,KOC M,KIZILTOPRAK H,TEKIN K,AYDEMIR E.Evaluation of topographic,tomographic,topometric,densitometric,and aberrometric features of cornea with pentacam HR system in subclinical keratoconus[J].Int Ophthalmol,2021,41(5):1729-1741.
[4] MCALINDEN C,KHADKA J,PESUDOVS K A comprehensive evaluation of the precision (repeatability and reproducibility) of the Oculus Pentacam HR[J].Invest Ophthalmol Vis Sci,2011,52(10):7731-7737.
[5] ESPORCATTE L P G,SALOMO M Q,LOPES B T,VINCIGUERRA P,VINCIGUERRA R,ROBERTS C,et al.Biomechanical diagnostics of the cornea[J].Eye Vis,2020,7:9.
[6] HERBER R,TERAI N,PILLUNAT K R,RAISKUP F,PILLUNAT L E,SPRL E.Dynamic Scheimpflug analyzer (Corvis ST) for measurement of corneal biomechanical parameters:apraxis-related overview[J].Ophthalmologe,2018,115(8):635-643.
[7] EVIK S G,KIVAN S A,AKOVA-BUDAK B,TOK-EVIK M.Relationship among corneal biomechanics,anterior segment parameters,and geometric corneal parameters[J].J Ophthalmol,2016,2016:8418613.
[8] LIU J,WANG Y,ZOU H,LI M.Influence of corneal shape parameters on corneal deformation responses measured with a Scheimpflug camera[J].Int Ophthalmol,2021,41(8):2853-2859.
[9] ABD EL-FATTAH E A,EL DORGHAMY A A,GHONEIM A M,SAAD H A.Comparison of corneal biomechanical changes after LASIK and F-SMILE with CorVis ST[J].Eur J Ophthalmol,2021,31(4):1762-1770.
[10] SEFAT S M,WILTFANG R,BECHMANN M,MAYER W J,KAMPIK A,KOOK D.Evaluation of changes in human corneas after femtosecond laser-assisted LASIK and small-incision lenticule extraction (SMILE) using non-contact tonometry and ultra-high-speed camera (corvis ST)[J].Curr Eye Res,2016,41(7):917-922.
[11] YU M,CHEN M,DAI J.Comparison of the posterior corneal elevation and biomechanics after SMILE and LASEK for myopia:a short- and long-term observation[J].Graefes Arch Clin Exp Ophthalmol,2019,257(3):601-606.
[12] SPADEA L,GIAMMARIA D,TRABUCCO P.Corneal wound healing after laser vision correction[J].Br J Ophthalmol,2016,100(1):28-33.
[13] FERNNDEZ J,RODRGUEZ-VALLEJO M,MARTNEZ J,TAUSTE A,SALVESTRINI P,PIERO D P.New parameters for evaluating corneal biomechanics and intraocular pressure after small-incision lenticule extraction by scheimpflug-based dynamic tonometry[J].J Cataract Refract Surg,2017,43(6):803-811.
[14] CAO K,LIU L,YU T,CHEN F,BAI J,LIU T.Changes in corneal biomechanics during small-incision lenticule extraction (SMILE) and femtosecond-assisted laser in situ keratomileusis (FS-LASIK)[J].Lasers Med Sci,2020,35(3):599-609.
[15] FERNNDEZ J,RODRGUEZ-VALLEJO M,MARTNEZ J,TAUSTE A,PIERO D P.Corneal thickness after SMILE affects scheimpflug-based dynamic tonometry[J].J Refract Surg,2016,32(12):821-828.
[16] WEI P,CHENG G P,ZHANG J,NG A L,CHAN T C,JHANJI V,et al.Changes in corneal volume at different areas and its correlation with corneal biomechanics after SMILE and FS-LASIK surgery[J].J Ophthalmol,2020,2020:1-7.
[17] SEDAGHAT M R,SHAREPOOR M,HASSANZADEH S,ABRISHAMI M.The corneal volume and biomechanical corneal factors:is there any orrelation?[J].J Res Med Sci,2012,17(1):32-39.
[18] VISWANATHAN D,KUMAR N L,MALES J J,GRAHAM S L.Relationship of structural characteristics to biomechanical profile in normal,keratoconic,and crosslinked eyes[J].Cornea,2015,34(7):791-796.
[19] DINIZ C M,HAZARBASSANOV R M,YAMAZAKI E,MURATA C,MALLMANN F,CAMPOS M.Pentacam Scheimpflug evaluation of corneal volume after LASIK[J].J Refract Surg,2010,26(8):600-604.
[20] CERVIO A,GONZALEZ-MEIJOME J M,FERRER-BLASCO T,GARCIA-RESUA C,MONTES-MICO R,PARAFITA M.Determination of corneal volume from anterior topography and topographic pachymetry:application to healthy and keratoconic eyes[J].Ophthalmic Physiol Opt,2009,29(6):652-660.
[21] REINSTEIN D Z,ARCHER T J,GOBBE M.Lenticule thickness readout for small incision lenticule extraction compared to Artemis three-dimensional very high-frequency digital ultrasound stromal measurements[J].J Refract Surg,2014,30(5):304-309.
[22] SHAH R,SHAH S,SENGUPTA S.Results of small incision lenticule extraction:all-in-one femtosecond laser refractive surgery[J].J Cataract Refract Surg,2011,37(1):127-137.
[23] A?CA A, DEMIROK A, CANKAYA K?, YA?A D, DEMIRCAN A, YILDIRIM Y, et al.Comparison of visual acuity and higher-order aberrations after femtosecond lenticule extraction and small-incision lenticule extraction[J].Contact Lens Anterior Eye,2014,37(4):292-296.
[24] WU W,WANG Y.The correlation analysis between corneal biomechanical properties and the surgically induced corneal high-order aberrations after small incision lenticule extraction and femtosecond laser in situ keratomileusis[J].J Ophthalmol,2015,2015:758196.
[25] WU W,WANG Y.Corneal higher-order aberrations of the anterior surface,posterior surface,and total cornea after SMILE,FS-LASIK,and FLEx surgeries[J].Eye Contact Lens,2016,42(6):358-365.
[26] JIN H Y,WAN T,YU X N,WU F,YAO K.Corneal higher-order aberrations of the anterior surface,posterior surface,and total cornea after small incision lenticule extraction (SMILE):high myopia versus mild to moderate myopia[J].BMC Ophthalmol,2018,18(1):1-9.
[27] JUHASZ E,KRANITZ K,SANDOR G L,GYENES A,TOTH G,NAGY Z Z.Wavefront properties of the anterior and posterior corneal surface after photorefractive keratectomy[J].Cornea,2014,33(2):172-176.
[28] GYLDENKERNE A,IVARSEN A,HJORTDAL J .Comparison of corneal shape changes and aberrations induced By FS-LASIK and SMILE for myopia[J].J Refract Surg,2015,31(4):223-229.
[29] NEMETH G,SZALAI E,HASSAN Z,LIPECZ A,FLASKO Z,MODIS L.Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas[J].Int J Ophthalmol,2017,10(2):217-222.

相似文献/References:

[1]李盼盼,管宇,陈诵惟,等.2.4 mm透明角膜单切口超声乳化白内障吸出术对角膜的影响[J].眼科新进展,2019,39(1):053.[doi:10.13389/j.cnki.rao.2019.0012]
 LI Pan-Pan,GUAN Yu,CHEN Song-Wei,et al.Effect of 2.4-mm clear corneal single-incision phacoemulsification on cornea[J].Recent Advances in Ophthalmology,2019,39(1):053.[doi:10.13389/j.cnki.rao.2019.0012]
[2]鲍先议,王勇,杨一涛,等.飞秒激光辅助的超声乳化手术对小梁切除术后并发性白内障患者角膜的影响[J].眼科新进展,2019,39(11):1076.[doi:10.13389/j.cnki.rao.2019.0247]
 BAO Xian-Yi,WANG Yong,YANG Yi-Tao,et al.Effect of femtosecond laser-assisted cataract phacoemulsification on cornea in complicated cataract patients after trabeculectomy[J].Recent Advances in Ophthalmology,2019,39(1):1076.[doi:10.13389/j.cnki.rao.2019.0247]
[3]刘欣,杨琳,谭凤玲,等.角膜生物力学分析仪及微视野计在原发性开角型青光眼患者早期诊断与病情评估中的应用[J].眼科新进展,2022,42(4):304.[doi:10.13389/j.cnki.rao.2022.0061]
 LIU Xin,YANG Lin,TAN Fengling,et al.Application of corneal biomechanics analyzer and microperimeter in early diagnosis and assessment of primary open-angle glaucoma[J].Recent Advances in Ophthalmology,2022,42(1):304.[doi:10.13389/j.cnki.rao.2022.0061]

备注/Memo

备注/Memo:
佛山市科技创新项目(编号:2020001005825);佛山市卫生健康局医学科研项目(编号:20220372)
更新日期/Last Update: 2024-01-05