参考文献/References:
[1] LIU Y C,WILKINS M,KIM T,MALYUGIN B,MEHTA J S.Cataracts[J].Lancent,2017,390(10094):600-612.
[2] NICHAMIN L D.Astigmatism control[J].Ophthalmol Clin North Am,2006,19(4):485-493.
[3] Chinese Medical Association Ophthalmology Branch cataract and intraocular lens group.Expert consensus on the clinical application of astigmatic correction intraocular lens in China (2017)[J].Chin J Ophthalmol,2017,53(1):7-10.
中华医学会眼科学分会白内障与人工晶状体学组.我国散光矫正型人工晶状体临床应用专家共识(2017年)[J].中华眼科杂志,2017,53(1):7-10.
[4] YANG L H,TANG X.The research progress in treating astigmatism at the time of cataract surgery[J].Chin J Ophthalmol,2011,47(6):573-576.
杨丽红,汤欣.白内障手术同时矫正术前散光的研究进展[J].中华眼科杂志,2011,47(6):573-576.
[5] TITIYAL J S,KAUR M,JOSE C P,FALERA R,KINKAR A,BAG-ESHWAR L M.Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking[J].Clin Ophthalmol,2018,12:747-753.
[6] NGUYEN T M,MILLER K M.Digital overlay technique for docu-menting toric intraocular lens axis orientation[J].J Cataract Refract Surg,2000,26(10):1496-1504.
[7] WANG X M,TANG X,ZHENG X H.Comparison of Toric intraocular lens axis marking using VERION image guided system and slit lamp observation[J].Rec Adv Ophthalmol,2018,38(2):153-155.
王晓明,汤欣,郑秀华.VERION数字导航系统行散光矫正型人工晶状体(Toric IOL)轴位标记与传统裂隙灯标记方法的对比研究[J].眼科新进展,2018,38(2):153-155.
[8] ELHOFI A H,HELALY H A.Comparison between digital and manual marking for toric intraocular lenses:a randomized trial[J].Medicine,2015,94(38):e1618.
[9] ZHOU X Y,WANG J,ZHAO J Y,ZHANG J S.Progress on cataract surgery navigation system[J].Chin J Ophthalmol Otorhinolaryngol,2017,17(2):101-104.
周星延,王静,赵江月,张劲松.白内障手术导航系统研究进展[J].中国眼耳鼻喉科杂志,2017,17(2):101-104.
[10] QIAN D W,GUO H K,JIN S L,ZHANG H Y,LI Y C.Femtosecond laser capsulotomy versus manual capsulotomy:a Meta-analysis[J].Int J Ophthalmol,2016,9(3):453-458.
[11] CAREY P J,LECCISOTTI A,MCGILLIGAN V E,GOODALL E A,MOORE C B.Assessment of toric intraocular lens alignment by a refractive power/corneal analyzer system and slitlamp observation[J].J Cataract Refract Surg,2010,36(2):222-229.
[12] DICK H B,SCHULTZ T.Laser-assisted marking for toric intraocular lens alignment[J].J Cataract Refract Surg,2016,42(1):7-10.
[13] WOO Y J,LEE H,KIM H S,KIM E K,SEO K Y,KIM T I.Comparison of 3 marking techniques in preoperative assessment of toric intraocular lenses using a wavefront aberrometer[J].J Cataract Refract Surg,2015,41(6):1232-1240.
[14] FAROOQUI J H,KOUL A,DUTTA R,SHROFF N M.Comparison of two different methods of preoperative marking for toric intraocular lens implantation:bubble marker versus pendulum marker[J].Int J Ophthalmol,2016,9(5):703-706.
[15] POPP N,HIRNSCHALL N,MAEDEL S,FINDL O.Evaluation of 4 corneal astigmatic marking methods[J].J Cataract Refract Surg,2012,38(12):2094-2099.
[16] MAYER W J,KREUTZER T,DIRISAMER M,KERN C,KORTUEM K,VOUNOTRYPIDIS E,et al.Comparison of visual outcomes,alignment accuracy,and surgical time between 2 methods of corneal marking for toric intraocular lens implantation[J].J Cataract Refract Surg,2017,43(10):1281-1286.
[17] LIN H Y,FANG Y T,CHUANG Y J,KARLIN J N,CHEN H Y,LIN S Y,et al.A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian[J].Clin Ophthalmol,2017,11:311-315.
[18] LI X P,GAO J W,WANG S,LI Y,LIU J.Clinical effect of phacoemulsification combined with intraocular lens implantation in management of primary angle-closure glaucoma with cataract[J].J Xinxiang Med Univ,2015,32(2):169-170,174.
李晓鹏,高建伟,王爽,李彦,刘静.白内障超声乳化联合人工晶状体植入术治疗原发性闭角型青光眼合并白内障临床疗效观察[J].新乡医学院学报,2015,32(2):169-170,174.
[19] LUO Y,LIU X,LU Y.Advances in precise position and navigation of functional intraocular lens[J].Chin J Ophthalmol Otorhinolaryngol,2017,17(2):105-109.
罗怡,刘馨,卢奕.功能性人工晶状体定位导航的研究进展[J].中国眼耳鼻喉科杂志,2017,17(2):105-109.
[20] HURA A S,OSHER R H.Comparing the Zeiss Callisto Eye and the Alcon Verion Image Guided System Toric Lens Alignment Technologies[J].J Refract Surg,2017,33(7):482-487.
[21] OSHER R H.Iris fingerprinting:new method for improving accuracy in toric lens orientation[J].J Cataract Refract Surg,2010,36(2):351-352.
[22] SHEN Z W,XUE L P,MO T,YIN H,JIANG L.Research advances in clinical application of Lenstar LS900[J].Int Eye Sci,2012,12(11):2123-2125.
沈政伟,薛林平,莫婷,尹禾,姜黎.Lenstar LS900的临床应用进展[J].国际眼科杂志,2012,12(11):2123-2125.
[23] ZHAO Y,LI L,ZHU S Q.Application of surgery guidance system on aspheric diffractive multifocal intraocular lenses implantation:a preliminary clinical observation[J].Ophthalmol CHN,2014(3):182-186.
赵阳,李蕾,朱思泉.手术导航系统在多焦点人工晶状体植入手术中的初步应用[J].眼科,2014(3):182-186.
[24] REITBLAT O,LEVY A,KLEINMANN G,ASSIA E I.Accuracy of intraocular lens power calculation using three optical biometry measurement devices:the OA-2000,Lenstar-LS900 and IOLMaster-500[J].Eye (Lond),2018,32(7):1244-1252.
[25] MYLONAS G,SACU S,BUEHL W,RITTER M,GEORGOPOULOS M,SCHMIDT-ERFURTH U.Performance of three biometry devices in patients with different grades of age-related cataract[J].Acta Ophthalmol,2011,89(3):e237-241.
[26] CHEN Y A,HIRNSCHALL N,FINDL O.Evaluation of 2 new optical biometry devices and comparison with the current gold standard biometer[J].J Cataract Refract Surg,2011,37(3):513-517.
[27] WANG Q,ZHANG H,TIAN F,LI Y T.Reproducibility of VERION Digital Guidance System and its comparability with iTrace,Lenstar LS900 and manual keratometer in measuring keratometry and astigmatism[J].Rec Adv Ophthalmol,2017,37(3):267-270.
王晴,张红,田芳,栗勇涛.VERION数字导航系统测量角膜曲率和散光的可重复性及其与iTrace、Lenstar LS900、手动角膜曲率计检测结果的一致性研究[J].眼科新进展,2017,37(3):267-270.
[28] SCHULTZ M,OBERHEIDE U,KERMANI O.Comparability of an image-guided system with other instruments in measuring corneal keratometry and astigmatism[J].J Cataract Refract Surg,2016,42(6):904-912.
[29] AVAKIAN A,OSHER R H.Rescue technique for salvaging toric intraocular lens alignment[J].J Cataract Refract Surg,2012,38(10):1716-1718.
[30] KANELLOPOULOS A J,ASIMELLIS G.Clinical correlation between placido,scheimpflug and LED color reflection topographies in imaging of a scarred cornea[J].Case Rep Ophthalmol,2014,5(3):311-317.
[31] KLIJN S,REUS N J,SICAM V A.Evaluation of keratometry with a novel Color-LED corneal topographer[J].J Refract Surg,2015,31(4):249-256.
[32] KANELLOPOULOS A J,ASIMELLIS G.Distribution and repeatability of corneal astigmatism measurements (Magnitude and Axis) evaluated with color light emitting diode reflection topography[J].Cornea,2015,34(8):937-944.
[33] ZHOU L,ZHANG J.Application of Pentacam in the cataract surgery[J].Int Eye Sci,2015,15(8):1358-1362.
周琳,张健.Pentacam在白内障手术中的应用[J].国际眼科杂志,2015,15(8):1358-1362.
[34] CRAWFORD A Z,PATEL D V,MCGHEE C N.Comparison and repeatability of keratometric and corneal power measurements obtained by Orbscan II,Pentacam,and Galilei corneal tomography systems[J].Am J Ophthalmol,2013,156(1):53-60.
[35] ZHENG Y J,YE Y J,XU R,WU L P,CHANG X K,CHEN H.Clinical effect of OPD-Scan Ⅲ marker methods in Toric intraocular lens implantation[J].Rec Adv Ophthalmol,2018,38(1):58-60.
郑亦君,叶应嘉,许荣,吴立平,常晓可,陈华.OPD-Scan Ⅲ标记法在Toric人工晶状体植入术中的临床效果[J].眼科新进展,2018,38(1):58-60.
[36] ZHANG Z,THOMAS L W,LEU S Y,CARTER S,GARG S.Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation[J].Indian J Ophthalmol,2017,65(9):813-817.
[37] EPITROPOULOS A T.Visual and refractive outcomes of a toric presbyopia-correcting intraocular lens[J].J Ophthalmol,2016,2016:7458210.
[38] WOODCOCK M G,LEHMANN R,CIONNI R J,BREEN M,SCOTT M C.Intraoperative aberrometry versus standard preoperative biometry and a toric IOL calculator for bilateral toric IOL implantation with a femtosecond laser:One-month results[J].J Cataract Refract Surg,2016,42(6):817-825.