[1]万佳昱,赵春梅,陈艳辉,等.散光矫正型人工晶状体轴位标记方法研究现状[J].眼科新进展,2019,39(11):1096-1100.[doi:10.13389/j.cnki.rao.2019.0252]
 WAN Jia-Yu,ZHAO Chun-Mei,CHEN Yan-Hui,et al.Status of axial position labeling methods for astigmatic correction type toric in traocular lens[J].Recent Advances in Ophthalmology,2019,39(11):1096-1100.[doi:10.13389/j.cnki.rao.2019.0252]
点击复制

散光矫正型人工晶状体轴位标记方法研究现状/HTML
分享到:

《眼科新进展》[ISSN:1003-5141/CN:41-1105/R]

卷:
39卷
期数:
2019年11期
页码:
1096-1100
栏目:
文献综述
出版日期:
2019-11-05

文章信息/Info

Title:
Status of axial position labeling methods for astigmatic correction type toric in traocular lens
作者:
万佳昱赵春梅陈艳辉刘湘云
063000 河北省唐山市,华北理工大学(万佳昱);唐山市眼科医院(赵春梅,陈艳辉,刘湘云)
Author(s):
WAN Jia-YuZHAO Chun-MeiCHEN Yan-HuiLIU Xiang-Yun
North China University of Science and Technology(WAN Jia-Yu),Tangshan Eye Hospital(ZHAO Chun-Mei,CHEN Yan-Hui,LIU Xiang-Yun),Tangshan 063000,Hebei Province,China
关键词:
白内障散光人工晶体轴位
Keywords:
cataractastigimatismintraocular lensaxial position
分类号:
R776.1
DOI:
10.13389/j.cnki.rao.2019.0252
文献标志码:
A
摘要:
在白内障术前对散光矫正型人工晶状体的轴位进行标记时,术者常采用传统标记方法,如:裂隙灯显微镜下水平标记、直视下手动标记等方法。近年来,随着飞秒激光辅助系统、导航系统等设备的不断发展,进一步完善了散光矫正型人工晶状体的标记方法,有助于提高该人工晶状体植入轴位的精准性,本文就白内障手术植入散光矫正型人工晶状体轴位标记方法研究方面的进展进行综述。
Abstract:
Traditional labeling methods such as horizontal labeling under slit lamp microscope and manual marking under direct vision are often used for axial position labeling method of astigmatism corrected toric intraocular lens before cataract operation.In recent years,the marking approach of the toric intraocular lens has further been improved as the aided system of femtosecond laser and navigation system and other related system constantly develop,which is beneficial to enhance the accuracy of implanted position for the toric intraocular lens.As for cataract surgery’s way of marking position in implanting the toric intraocular lens position of astigmatic correction,this article will comprehensively sum up the process of research aspects.

参考文献/References:

[1] LIU Y C,WILKINS M,KIM T,MALYUGIN B,MEHTA J S.Cataracts[J].Lancent,2017,390(10094):600-612.
[2] NICHAMIN L D.Astigmatism control[J].Ophthalmol Clin North Am,2006,19(4):485-493.
[3] Chinese Medical Association Ophthalmology Branch cataract and intraocular lens group.Expert consensus on the clinical application of astigmatic correction intraocular lens in China (2017)[J].Chin J Ophthalmol,2017,53(1):7-10.
中华医学会眼科学分会白内障与人工晶状体学组.我国散光矫正型人工晶状体临床应用专家共识(2017年)[J].中华眼科杂志,2017,53(1):7-10.
[4] YANG L H,TANG X.The research progress in treating astigmatism at the time of cataract surgery[J].Chin J Ophthalmol,2011,47(6):573-576.
杨丽红,汤欣.白内障手术同时矫正术前散光的研究进展[J].中华眼科杂志,2011,47(6):573-576.
[5] TITIYAL J S,KAUR M,JOSE C P,FALERA R,KINKAR A,BAG-ESHWAR L M.Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking[J].Clin Ophthalmol,2018,12:747-753.
[6] NGUYEN T M,MILLER K M.Digital overlay technique for docu-menting toric intraocular lens axis orientation[J].J Cataract Refract Surg,2000,26(10):1496-1504.
[7] WANG X M,TANG X,ZHENG X H.Comparison of Toric intraocular lens axis marking using VERION image guided system and slit lamp observation[J].Rec Adv Ophthalmol,2018,38(2):153-155.
王晓明,汤欣,郑秀华.VERION数字导航系统行散光矫正型人工晶状体(Toric IOL)轴位标记与传统裂隙灯标记方法的对比研究[J].眼科新进展,2018,38(2):153-155.
[8] ELHOFI A H,HELALY H A.Comparison between digital and manual marking for toric intraocular lenses:a randomized trial[J].Medicine,2015,94(38):e1618.
[9] ZHOU X Y,WANG J,ZHAO J Y,ZHANG J S.Progress on cataract surgery navigation system[J].Chin J Ophthalmol Otorhinolaryngol,2017,17(2):101-104.
周星延,王静,赵江月,张劲松.白内障手术导航系统研究进展[J].中国眼耳鼻喉科杂志,2017,17(2):101-104.
[10] QIAN D W,GUO H K,JIN S L,ZHANG H Y,LI Y C.Femtosecond laser capsulotomy versus manual capsulotomy:a Meta-analysis[J].Int J Ophthalmol,2016,9(3):453-458.
[11] CAREY P J,LECCISOTTI A,MCGILLIGAN V E,GOODALL E A,MOORE C B.Assessment of toric intraocular lens alignment by a refractive power/corneal analyzer system and slitlamp observation[J].J Cataract Refract Surg,2010,36(2):222-229.
[12] DICK H B,SCHULTZ T.Laser-assisted marking for toric intraocular lens alignment[J].J Cataract Refract Surg,2016,42(1):7-10.
[13] WOO Y J,LEE H,KIM H S,KIM E K,SEO K Y,KIM T I.Comparison of 3 marking techniques in preoperative assessment of toric intraocular lenses using a wavefront aberrometer[J].J Cataract Refract Surg,2015,41(6):1232-1240.
[14] FAROOQUI J H,KOUL A,DUTTA R,SHROFF N M.Comparison of two different methods of preoperative marking for toric intraocular lens implantation:bubble marker versus pendulum marker[J].Int J Ophthalmol,2016,9(5):703-706.
[15] POPP N,HIRNSCHALL N,MAEDEL S,FINDL O.Evaluation of 4 corneal astigmatic marking methods[J].J Cataract Refract Surg,2012,38(12):2094-2099.
[16] MAYER W J,KREUTZER T,DIRISAMER M,KERN C,KORTUEM K,VOUNOTRYPIDIS E,et al.Comparison of visual outcomes,alignment accuracy,and surgical time between 2 methods of corneal marking for toric intraocular lens implantation[J].J Cataract Refract Surg,2017,43(10):1281-1286.
[17] LIN H Y,FANG Y T,CHUANG Y J,KARLIN J N,CHEN H Y,LIN S Y,et al.A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian[J].Clin Ophthalmol,2017,11:311-315.
[18] LI X P,GAO J W,WANG S,LI Y,LIU J.Clinical effect of phacoemulsification combined with intraocular lens implantation in management of primary angle-closure glaucoma with cataract[J].J Xinxiang Med Univ,2015,32(2):169-170,174.
李晓鹏,高建伟,王爽,李彦,刘静.白内障超声乳化联合人工晶状体植入术治疗原发性闭角型青光眼合并白内障临床疗效观察[J].新乡医学院学报,2015,32(2):169-170,174.
[19] LUO Y,LIU X,LU Y.Advances in precise position and navigation of functional intraocular lens[J].Chin J Ophthalmol Otorhinolaryngol,2017,17(2):105-109.
罗怡,刘馨,卢奕.功能性人工晶状体定位导航的研究进展[J].中国眼耳鼻喉科杂志,2017,17(2):105-109.
[20] HURA A S,OSHER R H.Comparing the Zeiss Callisto Eye and the Alcon Verion Image Guided System Toric Lens Alignment Technologies[J].J Refract Surg,2017,33(7):482-487.
[21] OSHER R H.Iris fingerprinting:new method for improving accuracy in toric lens orientation[J].J Cataract Refract Surg,2010,36(2):351-352.
[22] SHEN Z W,XUE L P,MO T,YIN H,JIANG L.Research advances in clinical application of Lenstar LS900[J].Int Eye Sci,2012,12(11):2123-2125.
沈政伟,薛林平,莫婷,尹禾,姜黎.Lenstar LS900的临床应用进展[J].国际眼科杂志,2012,12(11):2123-2125.
[23] ZHAO Y,LI L,ZHU S Q.Application of surgery guidance system on aspheric diffractive multifocal intraocular lenses implantation:a preliminary clinical observation[J].Ophthalmol CHN,2014(3):182-186.
赵阳,李蕾,朱思泉.手术导航系统在多焦点人工晶状体植入手术中的初步应用[J].眼科,2014(3):182-186.
[24] REITBLAT O,LEVY A,KLEINMANN G,ASSIA E I.Accuracy of intraocular lens power calculation using three optical biometry measurement devices:the OA-2000,Lenstar-LS900 and IOLMaster-500[J].Eye (Lond),2018,32(7):1244-1252.
[25] MYLONAS G,SACU S,BUEHL W,RITTER M,GEORGOPOULOS M,SCHMIDT-ERFURTH U.Performance of three biometry devices in patients with different grades of age-related cataract[J].Acta Ophthalmol,2011,89(3):e237-241.
[26] CHEN Y A,HIRNSCHALL N,FINDL O.Evaluation of 2 new optical biometry devices and comparison with the current gold standard biometer[J].J Cataract Refract Surg,2011,37(3):513-517.
[27] WANG Q,ZHANG H,TIAN F,LI Y T.Reproducibility of VERION Digital Guidance System and its comparability with iTrace,Lenstar LS900 and manual keratometer in measuring keratometry and astigmatism[J].Rec Adv Ophthalmol,2017,37(3):267-270.
王晴,张红,田芳,栗勇涛.VERION数字导航系统测量角膜曲率和散光的可重复性及其与iTrace、Lenstar LS900、手动角膜曲率计检测结果的一致性研究[J].眼科新进展,2017,37(3):267-270.
[28] SCHULTZ M,OBERHEIDE U,KERMANI O.Comparability of an image-guided system with other instruments in measuring corneal keratometry and astigmatism[J].J Cataract Refract Surg,2016,42(6):904-912.
[29] AVAKIAN A,OSHER R H.Rescue technique for salvaging toric intraocular lens alignment[J].J Cataract Refract Surg,2012,38(10):1716-1718.
[30] KANELLOPOULOS A J,ASIMELLIS G.Clinical correlation between placido,scheimpflug and LED color reflection topographies in imaging of a scarred cornea[J].Case Rep Ophthalmol,2014,5(3):311-317.
[31] KLIJN S,REUS N J,SICAM V A.Evaluation of keratometry with a novel Color-LED corneal topographer[J].J Refract Surg,2015,31(4):249-256.
[32] KANELLOPOULOS A J,ASIMELLIS G.Distribution and repeatability of corneal astigmatism measurements (Magnitude and Axis) evaluated with color light emitting diode reflection topography[J].Cornea,2015,34(8):937-944.
[33] ZHOU L,ZHANG J.Application of Pentacam in the cataract surgery[J].Int Eye Sci,2015,15(8):1358-1362.
周琳,张健.Pentacam在白内障手术中的应用[J].国际眼科杂志,2015,15(8):1358-1362.
[34] CRAWFORD A Z,PATEL D V,MCGHEE C N.Comparison and repeatability of keratometric and corneal power measurements obtained by Orbscan II,Pentacam,and Galilei corneal tomography systems[J].Am J Ophthalmol,2013,156(1):53-60.
[35] ZHENG Y J,YE Y J,XU R,WU L P,CHANG X K,CHEN H.Clinical effect of OPD-Scan Ⅲ marker methods in Toric intraocular lens implantation[J].Rec Adv Ophthalmol,2018,38(1):58-60.
郑亦君,叶应嘉,许荣,吴立平,常晓可,陈华.OPD-Scan Ⅲ标记法在Toric人工晶状体植入术中的临床效果[J].眼科新进展,2018,38(1):58-60.
[36] ZHANG Z,THOMAS L W,LEU S Y,CARTER S,GARG S.Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation[J].Indian J Ophthalmol,2017,65(9):813-817.
[37] EPITROPOULOS A T.Visual and refractive outcomes of a toric presbyopia-correcting intraocular lens[J].J Ophthalmol,2016,2016:7458210.
[38] WOODCOCK M G,LEHMANN R,CIONNI R J,BREEN M,SCOTT M C.Intraoperative aberrometry versus standard preoperative biometry and a toric IOL calculator for bilateral toric IOL implantation with a femtosecond laser:One-month results[J].J Cataract Refract Surg,2016,42(6):817-825.

相似文献/References:

[1]乔建治 张永喜.抗青光眼术后白内障行不同切口超声乳化术的临床疗效分析[J].眼科新进展,2012,32(4):000.
[2]吴星.年龄相关性白内障患者超声乳化手术前后对比敏感度分析[J].眼科新进展,2012,32(6):000.
[3]王勇 叶应嘉 鲍先议 周龑丽 许荣 彭婷婷 曾志富.同轴微小切口超声乳化吸出术在青光眼滤过术后白内障摘出术中的应用[J].眼科新进展,2012,32(7):000.
[4]徐威.注射器针头囊袋内吸附劈核法在白内障手术中的应用[J].眼科新进展,2012,32(7):000.
[5]冉文瑛 陈静 张树利.抗青光眼术后不同角膜切口白内障超声乳化术对角膜屈光状态的影响[J].眼科新进展,2012,32(7):000.
[6]王运.常规连续模式超声乳化术与爆破模式冷超声乳化术治疗白内障的临床疗效比较[J].眼科新进展,2012,32(11):000.
[7]吴岩 于靖 朱玮 李艳红 巴俊 栗莉 赵莼.2011年上海市闸北区和田路小学学生散光状态及相关因素分析[J].眼科新进展,2013,33(1):000.
[8]徐冰 董宁 肖林 徐景美 褚利群 马骁.Toric人工晶状体植入术与球面人工晶状体植入联合周边角膜缘松解术矫正散光的对比研究[J].眼科新进展,2013,33(1):000.
[9]郭照洪 王宏 宋爱平 文译 侯祺 解柳.超声乳化白内障摘出联合人工晶状体植入治疗超高度轴性近视白内障患者的临床疗效[J].眼科新进展,2013,33(1):000.
[10]刘珣 王欣玲 柏全豪 张劲松 阎启昌.IOLMaster与四种人工晶状体屈光度计算公式的准确性研究[J].眼科新进展,2013,33(2):000.
[11]孔宁 陆晓和 李斌. 散光陡峭轴切口在白内障超声乳化多焦点人工晶状体植入术中的应用[J].眼科新进展,2014,34(2):184.
[12]陈祥菲,陆燕,段娴艺,等. Acry Sof IQ Restor Toric人工晶状体植入术后对视觉质量的影响[J].眼科新进展,2014,34(4):337.[doi:10.13389/j.cnki.rao.2014.0091]
[13]肖显文,张红,田芳. 双通道视觉质量分析系统评估Toric人工晶状体植入术后的视觉质量[J].眼科新进展,2014,34(4):345.[doi:10.13389/j.cnki.rao.2014.0093]
[14]蓝倩倩,李莉,王璐. 散光型人工晶状体治疗合并角膜散光的白内障临床对比分析[J].眼科新进展,2015,35(2):149.[doi:10.13389/j.cnki.rao.2015.0040]
 LAN Qian-Qian,LI Li,WANG Lu. Controlled clinical study of Toric intraocular lens in treatment of cataract with astigmatism[J].Recent Advances in Ophthalmology,2015,35(11):149.[doi:10.13389/j.cnki.rao.2015.0040]
[15]陈威,周婧,杜君,等.飞秒激光弧形角膜切开术对白内障合并角膜散光患者的矫正效果[J].眼科新进展,2019,39(12):1137.[doi:10.13389/j.cnki.rao.2019.0261]
 CHEN Wei,ZHOU Jing,DU Jun,et al.The effect of femtosecond-assisted arcuate keratotomy on cataract patients with corneal astigmatism[J].Recent Advances in Ophthalmology,2019,39(11):1137.[doi:10.13389/j.cnki.rao.2019.0261]

更新日期/Last Update: 2019-11-18