[1]黄秀旗,兰长骏,廖萱,等.双通道视觉质量分析系统在球面和非球面人工晶状体眼视觉质量评价中的应用[J].眼科新进展,2019,39(10):964-968.[doi:10.13389/j.cnki.rao.2019.0220]
 HUANG Xiu-Qi,LAN Chang-Jun,LIAO Xuan,et al.Evaluation of visual quality of spherical and aspheric intraocular lenses by dual channel optical quality analysis system[J].Recent Advances in Ophthalmology,2019,39(10):964-968.[doi:10.13389/j.cnki.rao.2019.0220]
点击复制

双通道视觉质量分析系统在球面和非球面人工晶状体眼视觉质量评价中的应用/HTML
分享到:

《眼科新进展》[ISSN:1003-5141/CN:41-1105/R]

卷:
39卷
期数:
2019年10期
页码:
964-968
栏目:
应用研究
出版日期:
2019-10-05

文章信息/Info

Title:
Evaluation of visual quality of spherical and aspheric intraocular lenses by dual channel optical quality analysis system
作者:
黄秀旗兰长骏廖萱林佳
401331 重庆市,重庆医科大学附属大学城医院眼科(黄秀旗);637000 四川省南充市,川北医学院附属医院眼科(兰长骏,廖萱,林佳)
Author(s):
HUANG Xiu-QiLAN Chang-JunLIAO XuanLIN Jia
Department of Ophthalmology,University-Town Hospital of Chongqing Medical University (HUANG Xiu-Qi),Chongqing 401331,China;Department of Ophthalmology,Affiliated Hospital of North Sichuan Medical College(LAN Chang-Jun,LIAO Xuan,LIN Jia),Nanchong 637000,Sichuan Province,China
关键词:
白内障人工晶状体非球面视觉质量OQAS
Keywords:
cataractintraocular lensasphericvisual qualityOQAS
分类号:
R776.1
DOI:
10.13389/j.cnki.rao.2019.0220
文献标志码:
A
摘要:
目的 使用双通道视觉质量分析系统(optical quality analysis system,OQAS)对球面和不同球差值非球面人工晶状体(intraocular lens,IOL)眼视觉质量进行评估。方法 选择白内障超声乳化及IOL植入术的年龄相关性白内障患者227例(349眼)分5组,分别植入Bausch & Lomb球面IOL Akreos Adapt、AMO球面IOL Sensar AR40E、Bausch & Lomb非球面IOL Akreos Adapt AO(球差值0 μm)、Alcon非球面IOL Acrysof IQ SN60WF(球差值-0.20 μm)、AMO非球面IOL Tecnis ZCB00(球差值-0.27 μm)。术后3个月采用双通道客观视觉质量分析系统(OQASTMⅡ)、KR-1W像差仪进行检查。比较各组客观散射指数(objective scatter index,OSI)、调制传递函数截止频率(MTF cut off)、斯特列尔比(Strehl ratio,SR)、模拟对比度视力(OV100%、OV20%、OV9%)波前像差。结果 术后3个月,5组间裸眼视力(uncorrected visual acuity,UCVA)、最佳矫正视力(best corrected visual acuity,BCVA)、等效球镜(spherical corrected,SE)比较差异均无统计学意义(均为P>0.05)。5组间角膜高阶像差差异均无统计学意义(均为P>0.05);4 mm瞳孔眼内球面像差(spherical aberration,SA)、全眼SA差异均有统计学意义(均为P<0.05);6 mm瞳孔眼内和全眼总高阶像差(total higher order aberration,tHOA)、SA差异均有统计学意义(均为P<0.05)。5组间OQAS参数差异均有统计学意义(均为P<0.05)。OSI:ZCB00组均优于AK组、AR40E组、AO组(均为P<0.05);MTF cut off:SN60WF组、ZCB00组均优于AK组、AR40E组(均为P<0.05);SR:SN60WF组、ZCB00组优于AK组(均为P<0.05);OV100%:SN60WF组、ZCB00组均优于AK组、AR40E组(均为P<0.05);OV20%:SN60WF组均优于AK组、AR40E组、AO组,ZCB00组均优于AK组(均为P<0.05);OV9%:SN60WF组、ZCB00组均优于AK组、AR40E组(均为P<0.05)。其余组间各指标差异均无统计学意义(均为P>0.05)。结论 非球面IOL眼视觉质量优于球面IOL眼;负球差非球面IOL AMO ZCB00和Alcon SN60WF优于零球差非球面IOL Bausch & Lomb Akreos AO;OQAS可以全面、客观地评价白内障术后IOL眼的视觉质量。
Abstract:
Objective To evaluation the vision quality of spherical and aspheric intraocular lenses (IOL) with different spherical differences by optical quaity analysis system (OQAS).Methods Totally 227 age-related cataract patients (349 eyes) with phacoemulsification and IOL implantation were collected in the research,and they were divided into five groups,followed by implantation with the Bausch&Lomb spherical IOL Akreos Adapt (AK group),AMO spherical IOL Sensar AR40E (AR40E group),Bausch&Lomb aspheric IOL Akreos Adapt AO (spherical aberration value was 0) (AO group),Alcon aspheric IOL Acrysof IQ SN60WF (spherical aberration value was -0.20 μm) (SN60WF group),AMO aspheric IOL Tecnis ZCB00 (spherical aberration value was -0.27 μm) (ZCB00 group),respectively.At 3 months after surgery,the visual and optical quality of pseudophakic eyes were measured by the OQASTMⅡ and the KR-1W aberrometer.Then,the parameters including objective scatter index (OSI),modulation transfer function (MTF-cutoff),strehl ratio (SR),100%,20%,9% contrast visual acuity (OV100%,OV20%,OV9%) and wave-front aberrations in each group.Results At 3 months after surgery,there was no significant difference in uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA) and spherical equivalent (SE) in the 5 groups (all P>0.05).There was no significant difference between the 5 groups in corneal high-order aberration (all P>0.05).There were significant differences in internal SA and ocular SA with 4 mm pupil between the 5 groups,there were significant differences between internal SA and ocular tHOA and ocular SA with 6 mm pupil (all P<0.05).For the parameters of OQAS,there were significant differences in the 5 groups (all P<0.05).The OSI was better in ZCB00 group than that in AK group,AR40E group and AO group (all P<0.05).MTF-cutoff was better in SN60WF group and ZCB00 group than that in AK group and AR40E group (all P<0.05).SR was better in SN60WF group and ZCB00 group than that in AK group (all P<0.05).OV100% was better in SN60WF group and ZCB00 group than that in AK group and AR40E group (all P<0.05).OV20% was better in SN60WF group than that in AK group,AR40E group and AO group,and ZCB00 group was better than AK group (all P<0.05);OV9% was better in SN60WF group and ZCB00 group than that in AK group and AR40E group (all P<0.05).Conclusion The vision quality of aspheric IOL is better than spherical IOL.The vision quality of AMO aspheric IOL ZCB00 and Alcon aspheric IOL SN60WF are better than Bausch & Lomb aspheric IOL Akreos AO.OQAS can be comprehensively and objectively to evaluate the visual quality of cataract patients after phacoemulsification and aspheric IOL implantation.

参考文献/References:

[1] SONG L,ZHU S Q.Clinical research progress of aspherical intraocular lens[J].Int Rev Ophthalmol,2006,30(1):14-18.
宋黎,朱思泉.非球面人工晶状体的临床研究进展[J].国际眼科纵览,2006,30(1):14-18.
[2] CHEN J,LUO L H,DUAN G P.Effect analysis of cataract surgery with transparent corneal incision in different by dual channel vision quality system[J].Rec Adv Ophthalmol,2017,37(3):251-254.
陈健,罗玲慧,段国平.双通道视觉质量系统评估不同方位白内障透明角膜切口手术疗效[J].眼科新进展,2017,37(3):251-254.
[3] DIAZ-DOUTOR F,BENITO A,PUJOL J,ARJONA M,GUELL J L,ARTAL P.Comparison of the retinal image quality with a Hartmann-Shack wavefront sensor and a double-pass instrument[J].Invest Ophthalmol Vis Sci,2006,47(4):1710-1716.
[4] XING X J,SONG H,TANG X.Repeatability of measurements with a double-pass OQAS system after 3 IOLs implantations[J].Chin J Paract Ophthalmol,2014,32(10):1163-1168.
邢晓杰,宋慧,汤欣.应用OQAS双通道系统对人工晶状体眼视觉质量评估可重复性研究[J].中国实用眼科杂志,2014,32(10):1163-1168.
[5] VILASECA M,ARJONA M,PUJOL J.Optical quality of foldable monofocal intraocular lenses before and after injection:comparative evaluation using a double-pass system[J].J Cataract Refract Surg,2009,35(8):1415-1423
[6] XU C C,XUE T,WANG Q M,ZHOU Y N,HUANG J H,YU A Y.Repeatability and reproducibility of a double-pass optical quality analysis device[J].PLoS One,2015,10(2):e0117587.
[7] MESTER U,DILLINGER P,ANTERIST N.Impact of a modified optic design on visual function:clinical comparative study[J].J Cataract Refract Surg,2003,29(4):652-660.
[8] NANAVATY M A,SPALTON D J,BOYCE J.Wavefront aberrations,depth of focus,and contrast sensitivity with aspheric and spherical intraocular lenses:fellow-eye study[J].J Cataract Refract Surg,2009,35(4):663-671.
[9] PARK C W,KIM H,JOO C K.Assessment of optical quality at different contrast levels in pseudophakic eyes[J].J Ophthalmol,2016:4247973.
[10] CHEN T,YU F,LIN H.Objective and subjective visual quality after implantation of all optic zone diffractive multifocal intraocularlenses:a prospective,case-control observational study[J].Br J Ophthalmol,2016,100(11):1530-1535.
[11] XIAO X W,ZHANG H,TIAN F.Evaluating visual quality after Toric intraocular lens implantation with double passage optical analysis system[J].Rec Adv Ophthalmol,2014,34(4):345-349.
肖显文,张红,田芳.双通道视觉质量分析系统评估Toric人工晶状体植入术后的视觉质量[J].眼科新进展,2014,34(4):345-349.
[12] YU A Y,SI E,WANG Q M,XU C C,ZHANG X X.Objective assessment of comprehensive optical quality among adults at different ages[J].Chin J Ophthalmol,2016,52(1):47-50.
俞阿勇,施恩,王勤美,许琛琛,张翔翔.不同年龄段成年人眼的综合光学质量客观评估[J].中华眼科杂志,2016,52(1):47-50.
[13] CHEN Y Y,YU A Y,XUE A Q,WANG S L,WANG Q M.A comparison of visual quality between two different anterior chamber phakic intraocular lens implants[J].Chin J Optomet Ophthalmol,2008,10(6):412-418.
陈云云,俞阿勇,薛安全,王树林,王勤美.两种前房型有晶状体眼人工晶状体植入术后视觉质量的比较[J].眼视光学杂志,2008,10(6):412-418.
[14] KAMIYA K,UMEDA K,KOBASHI H,SHIMIZU K,KAWAMORITA T,UOZATO H.Effect of aging on optical quality and intraocular scattering using the double-pass instrument[J].Curr Eye Res,2012,37(10):884-888.
[15] BEIKO G H,HAIGIS W,STEINMUELLER A.Distribution of corneal spherical aberration in a comprehensive ophthalmology practice and whether keratometry can predict aberration values[J].J Cataract Refract Surg,2007,33(5):848-858.
[16] WANG L,DAI E,KOCH D D.Optical aberrations of the human anterior cornea[J].J Cataract Refract Surg,2003,29(8):1514-1521.
[17] XIAO X W,TIAN F,ZHANG H.Clinical study of optical quality after implantation of aspheric toric intraocular lens in cataract surger[J].Chin J Ophthalmol,2015,51(4):263-269.
肖显文,田芳,张红.非球面Toric人工晶状体植入术后视觉质量的临床研究[J].中华眼科杂志,2015,51(4):263-269.
[18] LIU C L,WANG J,LI B,WU Q,LI Y M,JIA R,et al.Comparison of ocular scatter between intraocular lenses with different material and spheric aberration[J].Rec Adv Ophthalmol,2016,36(5):566-568.
刘春雷,王晶,李彬,武芹,栗映梅,贾茹,等.不同材料及球差人工晶状体眼散射比较分析[J].眼科新进展,2016,36(5):566-568.
[19] SONG H,XING X J,TANG X.OQAS system analysis of visual and optical performance of three kinds of multifocal IOLs[J].Chin J Pract Ophthalmol,2014,32(5):578-582.
宋慧,邢晓杰,汤欣.三种多焦点人工晶状体眼视觉功能和光学质量OQAS评估[J].中国实用眼科杂志,2014,32(5):578-582.
[20] DOANE J F,SLADE S G.An introduction to wavefront-guided refractive surgery[J].Int Ophthalmol Clin,2003,43(2):101-117.

相似文献/References:

[1]甄小妹 马忠旭 刘汝瑜 张娜 张伟 薛庆.全眼球差对人工晶状体眼视觉质量的作用[J].眼科新进展,2012,32(4):000.
[2]乔建治 张永喜.抗青光眼术后白内障行不同切口超声乳化术的临床疗效分析[J].眼科新进展,2012,32(4):000.
[3]王勇 叶应嘉 鲍先议 周龑丽 许荣 彭婷婷 余天.小切口经虹膜缝线固定后房型人工晶状体植入术治疗无晶状体眼[J].眼科新进展,2012,32(5):000.
[4]赵红 陈彬川 王永成 薛晓乐 赵焕.七叶洋地黄双苷滴眼液对不同年龄段人工晶状体眼伪调节力的影响[J].眼科新进展,2012,32(5):000.
[5]曹利群 王桂琴 彭秀军 李娜 卢成戎 贾洪真 石芊.疏水性和肝素修饰亲水性丙烯酸酯人工晶状体的临床应用效果对比[J].眼科新进展,2012,32(5):000.
[6]王勇 叶应嘉 鲍先议 周龑丽 许荣 彭婷婷 曾志富.同轴微小切口超声乳化吸出术在青光眼滤过术后白内障摘出术中的应用[J].眼科新进展,2012,32(7):000.
[7]冉文瑛 陈静 张树利.抗青光眼术后不同角膜切口白内障超声乳化术对角膜屈光状态的影响[J].眼科新进展,2012,32(7):000.
[8]王运.常规连续模式超声乳化术与爆破模式冷超声乳化术治疗白内障的临床疗效比较[J].眼科新进展,2012,32(11):000.
[9]郭照洪 王宏 宋爱平 文译 侯祺 解柳.超声乳化白内障摘出联合人工晶状体植入治疗超高度轴性近视白内障患者的临床疗效[J].眼科新进展,2013,33(1):000.
[10]张灿伟 黄旭东 姜雅琴 高婧 孙先勇 张杰 任建涛.α晶状体蛋白抗体与超声乳化术后前房炎症反应的相关性[J].眼科新进展,2013,33(6):000.
[11]吴星.年龄相关性白内障患者超声乳化手术前后对比敏感度分析[J].眼科新进展,2012,32(6):000.
[12]徐威.注射器针头囊袋内吸附劈核法在白内障手术中的应用[J].眼科新进展,2012,32(7):000.
[13]刘珣 王欣玲 柏全豪 张劲松 阎启昌.IOLMaster与四种人工晶状体屈光度计算公式的准确性研究[J].眼科新进展,2013,33(2):000.
[14]刘虹 马朋举.AcrySof Toric人工晶状体治疗白内障并矫正角膜散光的临床研究[J].眼科新进展,2012,32(1):000.
[15]惠玲 张自峰 王雨生 师晓莉.超声乳化术治疗高度近视白内障的临床观察[J].眼科新进展,2012,32(8):000.
[16]王勇 叶应嘉 鲍先议 周龑丽 许荣 彭婷婷 曾志富.视频监控联合标尺软件引导复曲面人工晶状体治疗白内障合并角膜散光[J].眼科新进展,2013,33(4):000.
[17]唐建 龚力力.白内障术后人工晶状体眼与正常眼高阶像差的内部相关性分析[J].眼科新进展,2013,33(11):000.
[18]梁兴国 张清琳.瞳孔粘连或闭锁的白内障超声乳化人工晶状体植入[J].眼科新进展,2009,29(1):000.
[19]李佳佳,陈彬川,帖红艳,等.白内障超声乳化吸出联合人工晶状体植入术高危因素临床分析[J].眼科新进展,2014,34(5):448.[doi:10.13389/j.cnki.rao.2014.0122]
 Ll Jia-Jia,CHEN Bin-Chuan,TIE Hong-Yan,et al.Risk factors of phacoemulsification with intraocular lens implantation[J].Recent Advances in Ophthalmology,2014,34(10):448.[doi:10.13389/j.cnki.rao.2014.0122]
[20]张蕾,谭荣强,周家承,等. 梅毒螺旋体感染患者白内障手术效果观察[J].眼科新进展,2014,34(7):684.[doi:10.13389/j.cnki.rao.2014.0188]

更新日期/Last Update: 2019-10-12