[1]李乃洋,陈毅华,易庚容,等.Opacity Lensmeter和Pentacam测量的晶状体密度与视力的相关性研究[J].眼科新进展,2019,39(9):838-839.[doi:10.13389/j.cnki.rao.2019.0190]
 LI Nai-Yang,CHEN Yi-Hua,YI Geng-Rong,et al.Correlation analysis between lens density and visual acuity by Opacity Lensmeter and Pentacam[J].Recent Advances in Ophthalmology,2019,39(9):838-839.[doi:10.13389/j.cnki.rao.2019.0190]
点击复制

Opacity Lensmeter和Pentacam测量的晶状体密度与视力的相关性研究/HTML
分享到:

《眼科新进展》[ISSN:1003-5141/CN:41-1105/R]

卷:
39卷
期数:
2019年9期
页码:
838-839
栏目:
应用研究
出版日期:
2019-09-05

文章信息/Info

Title:
Correlation analysis between lens density and visual acuity by Opacity Lensmeter and Pentacam
作者:
李乃洋陈毅华易庚容李晟范鲁博
528403 广东省中山市,中山市人民医院眼科中心
Author(s):
LI Nai-YangCHEN Yi-HuaYI Geng-RongLI ShengFAN Lu-Bo
Eye Centre,Zhongshan City People’s Hospital,Zhongshan 528403,Guangdong Province,China
关键词:
白内障晶状体密度视力
Keywords:
cataractlens densityvisual acuity
分类号:
R778.2
DOI:
10.13389/j.cnki.rao.2019.0190
文献标志码:
A
摘要:
目的 探讨Opacity Lensmeter(OLM)和Pentacam测量的晶状体密度值以及视力与其之间的相关性。方法 收集年龄相关核性白内障患者81例(81眼),检查最佳矫正视力(best corrected visual acuity,BCVA)(logMAR)后,分别用OLM和Pentacam测量晶状体密度,分析OLM和Pentacam测量的晶状体密度值及BCVA与其之间的相关性。结果 OLM和Pentacam测量的晶状体密度值与BCVA(logMAR)均呈正相关关系,且Pentacam测量的晶状体密度值与BCVA(logMAR)相关性更高(Z=2.068,P<0.05)。结论 晶状体密度可以反映晶状体混浊程度及视力损害程度。Pentacam比OLM测量的晶状体密度值与BCVA损害程度的相关性更高。
Abstract:
Objective To investigate the relationship between lens density (LD) measured with Opacity Lensmeter (OLM) and Pentacam as well as that between LD and visual acuity in age-related nuclear cataract patients.Methods Eighty-one patients(81 eyes) with age-related nuclear cataract were enrolled.The logMAR best corrected visual acuity (BCVA) was recorded.LD was evaluated by OLM and Pentacam.The relationship between LD measured with OLM and Pentacam as well as that between LD and logMAR BCVA were analyzed.Results There were a linear increasing relationship between logMAR BCVA and LD by OLM and Pentacam,respectively.The correlation between Pentacam and logMAR BCVA was stronger than that between OLM and logMAR BCVA (Z=2.068,P<0.05).Conclusion LD can be used for assessing visual damage in age-related nuclear cataract.A stronger correlation was observed between LD by Pentacam and logMAR BCVA than OLM.

参考文献/References:

[1] LI N Y,ZHAO Q,LENG X,LI Z T,CHEN Y H,LI S.Correlation of lens density and phacodynamics parameters in phacoemulsification[J].Rec Adv Ophthalmol,2018,38(2):136-138.
李乃洋,赵岐,冷炫,李中庭,陈毅华,李晟.晶状体密度与超声乳化动力学参数的量化关系[J].眼科新进展,2018,38(2):136-138.
[2] GUO Y,YAN H,ZHANG S B,NIU L E.Correlation analysis between anterior segment changes and refractive shift after cataract phacoemulsification by Pentacam system[J].Rec Adv Ophthalmol,2016,36(3):268-270.
郭勇,严宏,张少波,牛丽娥.应用Pentacam三维眼前节分析诊断系统对白内障超声乳化术后眼前节变化与屈光飘移的相关性分析[J].眼科新进展,2016,36(3):268-270.
[3] LIM D H,KIM T H,CHUNG E S,CHUNG T Y.Measurement of lens density using Scheimpflug imaging system as a screening test in the field of health examination for age-related cataract[J].Br J Ophthalmol,2015,99(2):184-191.
[4] LI Z T,LENG X,LI N Y,ZHAO Q,YU M B.Significances of host risk factors for acute angle-closure glaucoma[J].Rec Adv Ophthalmol,2018,38(11):1062-1065.
李中庭,冷炫,李乃洋,赵岐,余敏斌.急性闭角型青光眼发病相关危险因素研究[J].眼科新进展,2018,38(11):1062-1065.
[5] LIU Y,YUAN J.Vision quality after personalized implantation of aspheric intraocular lens[J].Rec Adv Ophthalmol,2016,36(1):35-37.
刘昳,袁进.个性化植入非球面人工晶状体术后视觉质量的临床观察[J].眼科新进展,2016,36(1):35-37.
[6] GRIESHABER M C,KOAK I,DUBLER B,FLAMMER J,ORGL S.Retrobulbar blood flow in patients with cataract[J].Br J Ophthalmol,2006,90(12):1512-1515.
[7] PEI X T,BAO Y Z,LI X X.Application of lens density measurement in grading diagnosis of age related cataract[J].Chin Ophthalmic Res,2009,27(1):49-54.
裴雪婷,鲍永珍,黎晓新.晶状体密度测量在年龄相关性白内障诊断中的价值探讨[J].眼科研究,2009,27(1):49-54.
[8] PANTHIER C,BURGOS J,ROUGER H,SAAD A,GATINEL D.New objective lens density quantification method using swept-source optical coherence tomography technology:Comparison with existing methods[J].J Cataract Refract Surg,2017,43(12):1575-1581.
[9] DREWS-BANKIEWICZ M A,CARUSO R C,DATILES M B,KAISER-KUPFER M I.Contrast sensitivity in patients with nuclear cataracts[J].Arch Ophthalmol,1992,110(7):953-959.
[10] DAVISON J A,CHYLACK L T.Clinical application of the Lens Opacities Classification System Ⅲ in the performance of phacoemulsification[J].J Cataract Refract Surg,2003,29(1):138-145.

相似文献/References:

[1]乔建治 张永喜.抗青光眼术后白内障行不同切口超声乳化术的临床疗效分析[J].眼科新进展,2012,32(4):000.
[2]吴星.年龄相关性白内障患者超声乳化手术前后对比敏感度分析[J].眼科新进展,2012,32(6):000.
[3]王勇 叶应嘉 鲍先议 周龑丽 许荣 彭婷婷 曾志富.同轴微小切口超声乳化吸出术在青光眼滤过术后白内障摘出术中的应用[J].眼科新进展,2012,32(7):000.
[4]徐威.注射器针头囊袋内吸附劈核法在白内障手术中的应用[J].眼科新进展,2012,32(7):000.
[5]冉文瑛 陈静 张树利.抗青光眼术后不同角膜切口白内障超声乳化术对角膜屈光状态的影响[J].眼科新进展,2012,32(7):000.
[6]王运.常规连续模式超声乳化术与爆破模式冷超声乳化术治疗白内障的临床疗效比较[J].眼科新进展,2012,32(11):000.
[7]郭照洪 王宏 宋爱平 文译 侯祺 解柳.超声乳化白内障摘出联合人工晶状体植入治疗超高度轴性近视白内障患者的临床疗效[J].眼科新进展,2013,33(1):000.
[8]刘珣 王欣玲 柏全豪 张劲松 阎启昌.IOLMaster与四种人工晶状体屈光度计算公式的准确性研究[J].眼科新进展,2013,33(2):000.
[9]张灿伟 黄旭东 姜雅琴 高婧 孙先勇 张杰 任建涛.α晶状体蛋白抗体与超声乳化术后前房炎症反应的相关性[J].眼科新进展,2013,33(6):000.
[10]唐东永 李霞 梁皓 何剑 谭少健.应用超声生物显微镜观察Bigbag人工晶状体在高度近视眼囊袋内的稳定性[J].眼科新进展,2013,33(6):000.
[11]李乃洋,赵岐,冷炫,等.晶状体密度与超声乳化动力学参数的量化关系[J].眼科新进展,2018,38(2):136.[doi:10.13389/j.cnki.rao.2018.0029]
 LI Nai-Yang,ZHAO Qi,LENG Xuan,et al.Correlation of lens density and phacodynamics parameters in phacoemulsification[J].Recent Advances in Ophthalmology,2018,38(9):136.[doi:10.13389/j.cnki.rao.2018.0029]

备注/Memo

备注/Memo:
国家自然科学基金项目(编号:8130073);广东省医学科研基金项目(编号:A2015041);中山市科技计划医疗卫生重大专项基金项目(编号:2015B1007、20122A003)
更新日期/Last Update: 2019-08-26