参考文献/References:
[1] SONG P,WANG H,THEODORATOU E,CHAN K Y,RUDAN I.The national and subnational prevalence of cataract and cataract blindness in China:a systematic review and meta-analysis[J].J Glob Health,2018,8(1):010804.
[2] CYPEL M C,SALOMO S R,DANTAS P E C,LOTTENBERG C L,KASAHARA N,RAMOS L R,et al.Vision status,ophthalmic assessment,and quality of life in the very old[J].Arq Bras Oftalmol,2017,80(3):159-164.
[3] MAHMUD I,KELLEY T,STOWELL C,HARIPRIYA A,BOMAN A,KOSSLER I,et al.A proposed minimum standard set of outcome measures for cataract surgery[J].JAMA Ophthalmol,2015,133(11):1247-1252.
[4] LI S,JIE Y.Cataract surgery and lens implantation[J].Curr Opin Ophthalmol,2019,30(1):39-43.
[5] De SILVA S R,EVANS J R,KIRTHI V,ZIAEI M,LEYLAND M.Multifocal versus monofocal intraocular lenses after cataract extraction[J].Cochrane Db Syst Rev,2016,12:CD003169.
[6] ALI J L,KAYMAK H,BREYER D,COCHENER B,PLAZA-PUCHE A B.Quality of life related variables measured for three multifocal diffractive intraocular lenses:a prospective randomised clinical trial[J].Clin Exp Ophthalmol,2018,46(4):380-388.
[7] MANGIONE C M,LEE P P,GUTIERREZ P R.Development of the 25-item National Eye Institute Visual Function Questionnaire[J].Arch Ophthalmol,2001,119(7):1050-1058.
[8] WANG C W,CHAN C L W,JIN H Y.Psychometric properties of the Chinese version of the 25-item National Eye Institute Visual Function Questionnaire[J].Optom Vis Sci,2008,85(11):1091-1099.
[9] CHAN C W,WONG D,LAM C L,MCGHEE S,LAI W W.Development of a Chinese version of the National Eye Institute Visual Function Questionnaire (CHI-VFQ-25) as a tool to study patients with eye diseases in Hong Kong[J].Br J Ophthalmol,2009,93(11):1431-1436.
[10] VENTER J A,BARCLAY D,PELOUSKOVA M.Initial experience with a new refractive rotationally asymmetric multifocal intraocular lens[J].J Refract Surg,2014,30(11):770-776.
[11] WANDELL B A.Foundations of vision[M].Sunderland,MA:Sinauer Associates,1995:157-161.
[12] WEN B W,LAN C J,LIAO X.Research progress on visual quality assessment methods[J].Rec Adv Ophthalmol,2017,37(8):793-796.
文佰伟,兰长骏,廖萱.视觉质量评价方法的研究进展[J].眼科新进展,2017,37(8):793-796.
[13] CAI X G,QIAO L Y,ZHANG Y,TAN J X,GUAN Z,WAN X H,et al.Reliability evaluation of double-pass optical quality analysis system and analysis of relevant influencing factors[J].Rec Adv Ophthalmol,2013,33(7):646-650.
蔡啸谷,乔利亚,张烨,谭家璿,管征,万修华,等.双通道视觉质量分析系统可靠性评价及相关影响因素分析[J].眼科新进展,2013,33(7):646-650.
[14] DAZ-DOUTN F,BENITO A,PUJOL J,ARJONA M,GELL J L,ARTAL P.Comparison of the retinal image quality with a Hartmann-Shack wavefront sensor and a double-pass instrument[J].Invest Ophthalmol Vis Sci,2006,47(4):1710-1716.
[15] VILASECA M,ROMERO M J,ARJONA M,LUQUE S O,ONDATEGUI J C,SALVADOR A,et al.Grading nuclear,cortical and posterior subcapsular cataracts using an objective scatter index measured with a double-pass system[J].Br J Ophthalmol,2012,96(9):1204-1210.
[16] ALBA-BUENO F,VEGA F,MILLN M S.Halos and multifocal intraocular lenses:origin and interpretation[J].Arch Soc Esp Oftalmol,2014,89(10):397-404.
[17] NIAN W Q,ZHOU Y F,HE Y F.Progress in the study of pseudophakic accommodation[J].Int Eye Sci,2012,12(1):72-74.
年婉青,周艳峰,何亚芬.人工晶状体眼调节力的研究进展[J].国际眼科杂志,2012,12(1):72-74.
[18] NAKAZAWA M,OHTSUKI K.Apparent accommodation in pseudophakic eyes after implantation of posterior chamber intraocular lenses[J].Am J Ophthalmol,1983,96(4):435-438.
[19] SIVAK J G.Accommodation in vertebrates:a contemporary survey[J].Curr Top Eye Res,1980,3:281-330.
[20] HOLLADAY J T,PRAGER T C,CHANDLER T Y,MUSGROVE K H,LEWIS J W,RUIZ R S.A three-part system for refining intraocular lens power calculations[J].J Cataract Refract Surg,1988,14(1):17-24.
[21] ZHANG D,FAN Z,GAO X,HUANG W,YANG Q,LI Z,et al.Illness uncertainty,anxiety and depression in Chinese patients with glaucoma or cataract[J].Sci Rep,2018,8(1):11671.
[22] WANG Y X.The application research of human psychological intervention model in diffractive multifocal intraocular lens implantation[D].Luzhou:Southwest Medical University,2016.
王妍茜.人性化心理干预模式在衍射型多焦点人工晶状体植入术中的应用研究[D].泸州:西南医科大学,2016.
相似文献/References:
[1]乔建治 张永喜.抗青光眼术后白内障行不同切口超声乳化术的临床疗效分析[J].眼科新进展,2012,32(4):000.
[2]吴星.年龄相关性白内障患者超声乳化手术前后对比敏感度分析[J].眼科新进展,2012,32(6):000.
[3]王勇 叶应嘉 鲍先议 周龑丽 许荣 彭婷婷 曾志富.同轴微小切口超声乳化吸出术在青光眼滤过术后白内障摘出术中的应用[J].眼科新进展,2012,32(7):000.
[4]徐威.注射器针头囊袋内吸附劈核法在白内障手术中的应用[J].眼科新进展,2012,32(7):000.
[5]冉文瑛 陈静 张树利.抗青光眼术后不同角膜切口白内障超声乳化术对角膜屈光状态的影响[J].眼科新进展,2012,32(7):000.
[6]王运.常规连续模式超声乳化术与爆破模式冷超声乳化术治疗白内障的临床疗效比较[J].眼科新进展,2012,32(11):000.
[7]郭照洪 王宏 宋爱平 文译 侯祺 解柳.超声乳化白内障摘出联合人工晶状体植入治疗超高度轴性近视白内障患者的临床疗效[J].眼科新进展,2013,33(1):000.
[8]刘珣 王欣玲 柏全豪 张劲松 阎启昌.IOLMaster与四种人工晶状体屈光度计算公式的准确性研究[J].眼科新进展,2013,33(2):000.
[9]张灿伟 黄旭东 姜雅琴 高婧 孙先勇 张杰 任建涛.α晶状体蛋白抗体与超声乳化术后前房炎症反应的相关性[J].眼科新进展,2013,33(6):000.
[10]唐东永 李霞 梁皓 何剑 谭少健.应用超声生物显微镜观察Bigbag人工晶状体在高度近视眼囊袋内的稳定性[J].眼科新进展,2013,33(6):000.
[11]赵佳钰,刘华,龚蕤,等.区域折射型多焦点人工晶状体植入术后白内障患者视觉质量初步评价[J].眼科新进展,2021,41(5):470.[doi:10.13389/j.cnki.rao.2021.0098]
ZHAO Jiayu,LIU Hua,GONG Rui,et al.Preliminary evaluation of visual quality of cataract patients after rotationally asymmetric multifocal IOLs implantation[J].Recent Advances in Ophthalmology,2021,41(8):470.[doi:10.13389/j.cnki.rao.2021.0098]