[1]王晓明,汤欣,郑秀华.VERION数字导航系统行散光矫正型人工晶状体(Toric IOL)轴位标记与传统裂隙灯标记方法的对比研究[J].眼科新进展,2018,38(2):153-155.[doi:10.13389/j.cnki.rao.2018.0034]
 WANG Xiao-Ming,TANG Xin,ZHENG Xiu-Hua.Comparison of Toric intraocular lens axis marking using VERION image guided system and slit lamp observation[J].Recent Advances in Ophthalmology,2018,38(2):153-155.[doi:10.13389/j.cnki.rao.2018.0034]
点击复制

VERION数字导航系统行散光矫正型人工晶状体(Toric IOL)轴位标记与传统裂隙灯标记方法的对比研究/HTML
分享到:

《眼科新进展》[ISSN:1003-5141/CN:41-1105/R]

卷:
38卷
期数:
2018年2期
页码:
153-155
栏目:
应用研究
出版日期:
2018-02-05

文章信息/Info

Title:
Comparison of Toric intraocular lens axis marking using VERION image guided system and slit lamp observation
作者:
王晓明汤欣郑秀华
300020 天津市,天津医科大学眼科临床学院 天津市眼科医院 天津市眼科研究所 天津市眼科学与视觉科学重点实验室(王晓明,汤欣);250200 山东省济南市,济南市明水眼科医院(王晓明,郑秀华)
Author(s):
WANG Xiao-MingTANG XinZHENG Xiu-Hua
Clinical College of Ophthalmology,Tianjin Medical University,Tianjin Eye Hospital,Tianjin Key Laboratory of Ophthalmology and Visual Science,Tianjin Eye Institute(WANG Xiao-Ming,TANG Xin),Tianjin 300020,China;Jinan Mingshui Eye Hospital(WANG Xiao-Ming,ZHENG Xiu-Hua),Jinan 250200,Shandong Province,China
关键词:
VERION数字导航系统角膜散光轴位标记白内障人工晶状体
Keywords:
VERION image guided systemcorneal astigmatismaxis markingcataractIOL
分类号:
R776.1
DOI:
10.13389/j.cnki.rao.2018.0034
文献标志码:
A
摘要:
目的 评价VERION数字导航系统行散光矫正型人工晶状体(Toric intraocular lens,Toric IOL)轴位标记的准确性和有效性。方法 回顾性分析2016年6月至2017年5月行白内障超声乳化摘出联合Toric IOL植入术的患者75例(75眼),所有患者术前应用VERION数字导航系统采集眼前节图像并设定IOL预设植入轴位(目标轴位),并于裂隙灯下采用1 mL注射器针头标记水平轴位。术中随机参考VERION导航下的IOL目标轴位或裂隙灯下标记的目标轴位植入IOL,记为VERION组(42眼)和裂隙灯组(33眼),术后1 d、1周、1个月、3个月记录患者最佳矫正视力,散瞳后进行眼前节照相,应用Photoshop软件进行图像分析,比较两组患者术后不同时间点的最佳矫正视力以及IOL实际轴位与目标轴位的偏差值。结果 VERION组术后1 d、1周、1个月、3个月最佳矫正视力≥0.8的眼数所占比例分别为61.9%、78.6%、71.4%、76.2%,裂隙灯组分别为69.7%、78.8%、81.8%、75.8%,各时间点两组相比差异均无统计学意义(均为P>0.05)。VERION系统标记的IOL目标轴位与裂隙灯下针头标记的IOL目标轴位的差值为(3.04±1.99)°。两组患者术后不同时间点IOL实际轴位与目标轴位的偏差值均无统计学意义(均为P>0.05)。结论 应用VERION数字导航系统行Toric IOL轴位标记,术后效果准确稳定。
Abstract:
Objective To evaluate the accuracy and validity of Toric intraocular lens (IOL) alignment by VERION image guided system.Methods In this retrospective study,75 eyes of 75 patients who underwent phacomulsification combined with Toric IOL implantation were enrolled from June 2016 to May 2017.Before operation,anterior segment images of all patients were collected using VERION image guided system,and target axis of IOL implantation was set.Horizontal axis was marked using 1 mL syringe needle under the slit lamp.During the procedures,the IOL was implanted referring to the target axis under VERION system or the slit lamp randomly,and there were 42 eyes with IOL implantation guided by VERION system (VERION group),and 33 eyes guided by slit lamp (slit lamp group).The best corrected visual acuity(BCVA)of each patient was recorded at day 1,1 week,1 month,and 3 months after operation.Anterior segment images were taken after mydriasis,and all the images were analyzed by Photoshop software.Finally,the BCVA at various time points after operation and the deviation value of actual axis and target axis was compared in both groups.Results The proportion of eyes with BCVA ≥ 0.8 at day 1,1 week,1 month,and 3 months after operation was 61.9%,78.6%,71.4% and 76.2% in VERION group,respectively,and 69.7%,78.8%,81.8% and 75.8% in slit lamp group,respectively,and there was no statistical significance between VERION group and slit lamp group (all P>0.05).The difference value of target axis marked by VERION system and by slit lamp was (3.04±1.99) °.No significant differences were seen in the IOL actual axis and target axis between the two groups at various time points (all P>0.05).Conclusion It is accurate and stable of VERION image guided system for toric IOL axis marking.

参考文献/References:

[1] CHEN W,ZUO C,CHEN C,SU J,LUO L,CONGDON N,et al.Prevalence of corneal astigmatism before cataract surgery in Chinese patients[J].J Cataract Refract Surg,2013,39(2):188-192.
[2] YUAN X,SONG H,PENG G,HUA X,TANG X.Prevalence of corneal astigmatism in patients before cataract surgery in northern China[J].J Ophthalmol,2014,2014:536412.
[3] CAREY PJ,LECCISOTTI A,MCGILLIGAN VE,GOODALL EA,MOORE CB.Assessment of toric intraocular lens alignment by a refractive power/corneal analyzer system and slit lamp observation[J].J Cataract Refract Surg,2010,36(2):222-229.
[4] POPP N,HIRNSCHALL N,MAEDEL S,FINDL O.Evaluation of 4 corneal astigmatic marking methods[J].J Cataract Refract Surg,2012,38(12):2094-2099.
[5] WOO YJ,LEE H,KIM HS,KIM EK,SEO KY,KIM TI.Comparison of 3 marking techniques in preoperative assessment of toric intraocular lenses using a wavefront aberrometer[J].J Cataract Refract Surg,2015,41(6):1232-1240.
[6] FAROOQUI JH,KOUL A,DUTTA R,SHROFF NM.Comparison of two different methods of preoperative marking for toric intraocular lens implantation:bubble marker versus pendulum marker[J].Int J Ophthalmol,2016,9(5):703-706.
[7] NGUYEN TM,MILLER KM.Digital overlay technique for documenting toric intraocular lens axis orientation[J].J Cataract Refract Surg,2000,26(10):1496-1504.
[8] MA JJ,TSENG SS.Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation[J].J Cataract Refract Surg,2008,34(10):1631-1636.
[9] KIM H,JOO CK.Ocular cyclotorsion according to body position and flap creation before laser in situ keratomileusis[J].J Cataract Refract Surg,2008,34(4):557-561.
[10] PRICKETT AL,BUI K,HALLAK J,BAKHTIYARI P,CRUZ J,AZAR DT,et al.Cyclotorsional and non-cyclotorsional components of eye rotation observed from sitting to supine position[J].Br J Ophthalmol,2015,99(1):49-53.
[11] WANG Q,ZHANG H,TIAN F,LI YT.Reproducibility of VERION digital guidance system and its comparability with iTrace,Lenstar LS900 and manual keratometer in measuring keratometry and astigmatism[J].Rec Adv Ophthalmol,2017,37(3):267-270.
王晴,张红,田芳,栗勇涛.VERION数字导航系统测量角膜曲率和散光的可重复性及其与iTrace、Lenstar LS900、手动角膜曲率计检测结果的一致性研究[J].眼科新进展,2017,37(3):267-270.
[12] ZHOU XY,WANG J,ZHAO JY,ZHANG XD,ZHANG JS.Comparative study of Verion on eye position for sit and clinostatism and slit lamp marking[C]// Zhejiang Medical Doctors Association,Zhejiang Medical Doctors Association Ophthalmologist Association.The west lake international summit forum of cataract & intraocular lens proceedings:Hangzhou,China:2015:63-64.
周星延,王静,赵江月,张晓丹,张劲松.Verion对坐、卧位眼位及与裂隙灯标记的比较研究[C]//浙江省医师协会,浙江省医师协会眼科医师分会.西湖国际白内障及人工晶状体高峰论坛论文汇编:中国杭州:2015:63-64.
[13] LIN HY,FANG YT,CHUANG YJ,KARLIN JN,CHEN HY,LIN SY,et al.A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian[J].Clin Ophthalmol,2017,11:311-315.
[14] ELHOFI AH,HELALY HA.Comparison between digital and manual marking for toric intraocular lenses:a randomized trial[J].Medicine (Baltimore),2015,94(38):e1618.

相似文献/References:

[1]刘虹 马朋举.AcrySof Toric人工晶状体治疗白内障并矫正角膜散光的临床研究[J].眼科新进展,2012,32(1):000.
[2]王勇 叶应嘉 鲍先议 周龑丽 许荣 彭婷婷 曾志富.视频监控联合标尺软件引导复曲面人工晶状体治疗白内障合并角膜散光[J].眼科新进展,2013,33(4):000.
[3]李晓红 张铁民.“T”切口对白内障伴高度角膜散光患者视功能和生存质量的影响[J].眼科新进展,2013,33(12):000.
[4]张奇. 白内障小切口超声乳化联合角膜缘松解术矫正角膜散光的疗效分析[J].眼科新进展,2014,34(7):678.[doi:10.13389/j.cnki.rao.2014.0186]
[5]郭琳,马波. IOLMaster、角膜地形图及Pentacam测量年龄相关性白内障患者角膜散光的比较[J].眼科新进展,2014,34(9):868.[doi:10.13389/j.cnki.rao.2014.0240]
[6]冯珂,郭海科,张英朗,等.白内障术前两种角膜散光标记方法的对比研究[J].眼科新进展,2016,36(8):748.[doi:10.13389/j.cnki.rao.2016.0199]
 FENG Ke,GUO Hai-Ke,ZHANG Ying-Lang,et al.Comparative study of two corneal astigmatism marker methods before cataract surgery[J].Recent Advances in Ophthalmology,2016,36(2):748.[doi:10.13389/j.cnki.rao.2016.0199]
[7]王晴,张红,田芳,等.VERION数字导航系统测量角膜曲率和散光的可重复性及其与iTrace、Lenstar LS900、手动角膜曲率计检测结果的一致性研究[J].眼科新进展,2017,37(3):267.[doi:10.13389/j.cnki.rao.2017.0067]
 WANG Qing,ZHANG Hong,TIAN Fang,et al.Reproducibility of VERION Digital Guidance System and its comparability with iTrace,Lenstar LS900 and manual keratometer in measuring keratometry and astigmatism[J].Recent Advances in Ophthalmology,2017,37(2):267.[doi:10.13389/j.cnki.rao.2017.0067]
[8]王越,柯敏,王文欢,等.年龄相关性白内障患者眼轴长度与角膜曲率、角膜散光、前房深度和眼压的关系[J].眼科新进展,2017,37(9):879.[doi:10.13389/j.cnki.rao.2017.0223]
 WANG Yue,KE Min,WANG Wen-Huan,et al.Effects of axial length on corneal curvature,corneal astigmatism,anterior chamber depth and intraocular pressure in age-related cataract[J].Recent Advances in Ophthalmology,2017,37(2):879.[doi:10.13389/j.cnki.rao.2017.0223]
[9]代志强,王保君,杨华,等.巩膜瓣可调整缝线的小梁切除术对角膜散光的影响[J].眼科新进展,2017,37(9):882.[doi:10.13389/j.cnki.rao.2017.0224]
 DAI Zhi-Qiang,WANG Bao-Jun,YANG Hua,et al.Effects of trabeculectomy with removable suture in sclera flap on astigmatism of cornea[J].Recent Advances in Ophthalmology,2017,37(2):882.[doi:10.13389/j.cnki.rao.2017.0224]
[10]陈佳惠,张帆,景清荷,等.不同年龄段马凡综合征晶状体不全脱位患者角膜特征及意义[J].眼科新进展,2017,37(11):1036.[doi:10.13389/j.cnki.rao.2017.0262]
 CHEN Jia-Hui,ZHANG Fan,JING Qing-He,et al.Corneal characteristics in Marfan syndrome patients of different ages with lens subluxation and their significance[J].Recent Advances in Ophthalmology,2017,37(2):1036.[doi:10.13389/j.cnki.rao.2017.0262]

更新日期/Last Update: 2018-02-02