[1]李勇,李晶,魏升升,等.正常角膜伴近视散光眼角膜各形态参数分布特征及与全眼屈光参数的关系[J].眼科新进展,2016,36(1):050-52.[doi:10.13389/j.cnki.rao.2016.0014]
 LI Yong,LI Jing,WEI Sheng-Sheng,et al.Investigation of corneal shape parameters distribution in normd cornea with myopic astigmatism and correlation with ocular refractive parameters[J].Recent Advances in Ophthalmology,2016,36(1):050-52.[doi:10.13389/j.cnki.rao.2016.0014]
点击复制

正常角膜伴近视散光眼角膜各形态参数分布特征及与全眼屈光参数的关系
分享到:

《眼科新进展》[ISSN:1003-5141/CN:41-1105/R]

卷:
36卷
期数:
2016年1期
页码:
050-52
栏目:
应用研究
出版日期:
2016-01-05

文章信息/Info

Title:
Investigation of corneal shape parameters distribution in normd cornea with myopic astigmatism and correlation with ocular refractive parameters
作者:
李勇李晶魏升升万雅群叶璐李娟刘建国
710004 陕西省西安市,西安市第四医院眼科激光视力矫正中心
Author(s):
LI Yong LI JingWEI Sheng-Sheng WAN Ya-QunYE Lu LI Juan LIU Jian-Guo
Refraaive Surgery Center, Department of Ophthalmology , Xi ’ an No. 4 Hospital, Xi ’ an 710004, Shaanxi Province . China
关键词:
角膜形态Pentacam眼前节分析全眼屈光参数角膜屈光手术近视散光
Keywords:
corneal shape Pentacam scheimpflug system ocular refractive parameters corneal refractive surgery myopic astigmatism
DOI:
10.13389/j.cnki.rao.2016.0014
文献标志码:
A
摘要:
目的 探讨正常角膜伴近视散光眼角膜各形态参数分布特征及与全眼屈光参数的关系。方法 收集102例(204眼)近视患者,分别应用非接触眼压计、检影仪、A超、角膜超声测厚仪、Pentacam三维眼前节分析仪进行眼压、屈光度、眼轴长度、角膜厚度、角膜前后表面形态参数等测量,应用SPSS13.0统计学软件进行数据分析。结果 正常角膜伴近视散光眼角膜中央厚度(537.06±25.45)μm,角膜中央前表面高度(2.35±1.39)μm,中央后表面高度(3.60±2.73)μm,角膜Q值(8mm范围)-0.30±0.10,角膜最薄点距角膜顶点距离(0.59±0.19)mm,角膜最薄点位置多位于角膜顶点颞下方,占91.67%。角膜最薄点至周边厚度增长变化指数为1.04±0.13。角膜中央前后表面高度、角膜Q值、角膜最薄点至周边厚度增长变化指数与等效球镜、眼压、眼轴长度无明显相关性(均为P>0.05)。结论 正常角膜伴近视散光眼角膜形态各项参数分布值各有特点,与全眼屈光参数无明显相关性。
Abstract:
Objective To investigate the distribution and characteristics of normal corneal shape parameters in myopic astigmatism as well as relationship with ocular refractive parameters. Methods A total of 102 myopic patients ( 204 eyes) with astigmatism were collected. and the intraocular pressure , refraction , ocular axis length , corneal thickness,anterior and posterior corneal surface shape were measured with noncontact tonometer , mydriatic optometry , A-scan , Pentacam scheimpflug system and ultrasonic pachymeter,respectively. The data was analyzed by SPSS 13. 0 software. Results The corneal central thickness was (537. 06 +25. 45 ) ym, the corneal central anterior surface elevation and posterior surface elevation were ( 2. 35 + 1. 39) ym and ( 3. 60 +2. 73) ym. The mean corneal Q value with 8 mm was - 0. 30 +0. 10 . the mean distance of corneal apex and corneal thinnest thickness was ( 0. 59 + 0. 19 ) mm. and the thinnest thickness mostly located in the temporal inferior of the apex mostly (91. 67% ) . The Pachymetric progression index average was l. 04 + 0. 13. There was no significant correlation between corneal anterior surface elevation , posterior surface elevation, Q value, pachymetric progression index average and spherical equivalent, intraocular pressure , ocular axis length , respectively ( all P > 0. 05 ) . Conclusion Characteristic of corneal shape parameters distribution in normal cornea with myopic astigmatism are not identical. There was no significant difference between corneal shape parameters of myopic patients and total ocular refractive parameters.

备注/Memo

备注/Memo:
西安市社发-医学攻关项目[编号:SF1315(3)];陕西省卫生科研项目(编号:2014D49)
更新日期/Last Update: 2016-01-04