[1]向菁,管怀进.人工晶状体计算公式的研究进展[J].眼科新进展,2018,38(6):583-587.[doi:10.13389/j.cnki.rao.2018.0138]
 XIANG Jing,GUAN Huai-Jin.Research progress on the calculation formulas of IOL[J].Recent Advances in Ophthalmology,2018,38(6):583-587.[doi:10.13389/j.cnki.rao.2018.0138]
点击复制

人工晶状体计算公式的研究进展/HTML
分享到:

《眼科新进展》[ISSN:1003-5141/CN:41-1105/R]

卷:
38卷
期数:
2018年6期
页码:
583-587
栏目:
文献综述
出版日期:
2018-06-05

文章信息/Info

Title:
Research progress on the calculation formulas of IOL
作者:
向菁管怀进
226001 江苏省南通市,南通大学附属医院眼科
Author(s):
XIANG JingGUAN Huai-Jin
Ophthalmology,Affiliated Hospital of Nantong University,Natong 226001,Jiangsu Province,China
关键词:
人工晶状体计算公式进展
Keywords:
IOL calculation formulas progress
分类号:
R776
DOI:
10.13389/j.cnki.rao.2018.0138
文献标志码:
A
摘要:
白内障手术已从防盲性手术时代进入屈光性手术时代,人工晶状体(intraocular lenses,IOL)的制定影响患者术后脱镜率及视觉质量,其中IOL度数的计算公式的选择又直接影响着IOL的制定,本文主要就IOL球镜及其柱镜计算公式的最新研究进展予以综述。
Abstract:
The purpose of cataract surgery has been raised from blindness prevention to refractive correction.As the quality of IOL impacts postoperative refractive outcomes,IOL plays a vital role in the surgery.Besides,the choice of calculation formulas of IOL influences the quality of IOL.Accordingly,this article aims to give a review on the latest research progress of IOL calculation formulas.

参考文献/References:

[1] Cataract and Intraocular Lens Group of Chinese Ophthalmologyical Society.Expert on consensus on clinical application of astigmatism corrected intraocular lenses in China(2017)[J].Chin J Ophthalmol,2017,53(1):7-10.
中华医学会眼科学分会白内障与人工晶状体学组.我国散光矫正型人工晶状体临床应用专家共识(2017年) [J].中华眼科杂志,2017,53(1):7-10.
[2] YU A Y.Challenges of refractive cataract surgery[J].Chin J Optom Ophthalmol Vis Sci,2017,19(2):65-70.
俞阿勇.屈光性白内障手术的若干挑战[J].中华眼视光学与视觉科学杂志,2017,19(2):65-70.
[3] KOCH D D,HILL W,ABULAFIA A,WANG L.Pursuing perfection in intraocular lens calculations:I.Logical approach for classifying IOL calculation formulas[J].J Cataract Refract Surg,2017,43(6):717-718.
[4] OLSEN T.Pre- and postoperative refraction after cataract extraction with implantation of standard power[J].Br J Ophthalmo,1988,72(1):231-235.
[5] THOMPSN J T,MAUMENEE A E,BAKER C C.A new posterior chamber intraocular lens formula for axial myopes[J].Ophthalmology,1984,91(5):484-488.
[6] OLSEN T.Calculation of intraocular lens power:a review[J].Acta Ophthalmol Scand,2007,85(5):472-485.
[7] SANDERS D R,RETZLAFF J A,KRAFF M C,GIMBEL H V,RAANAN M G.Comparison of the SRK/T formula and other theoretical and regression formulas[J].J Cataract Refract Surg,1990,16(3):341-346.
[8] ARISTODEMOU P,KNOX CARTWRIGHT N E,SPARROW J M,JOHNSTON R L.Formula choice:Hoffer Q,Holladay 1,or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry[J].J Cataract Refract Surg,2011,37:63-71.
[9] OLSEN T,HOFFMANN P.C constant:new concept for ray tracing- assisted intraocular lens power calculation[J].J Cataract Refract Surg,2014,40:764-773.
[10] THOMAS B C,MUELLER A,AUFFARTH G U,HOLZER M P.Influence on intraocular lens power calculation of corneal radii measurement using an image-guided system[J].J Cataract Refract Surg,2016,42(11):1588-1594.
[11] COOKE D L,COOKE T L.Comparison of 9 intraocular lens power calculation formulas[J].J Cataract Refract Surg,2016,42(8):1157-64.
[12] TANG X,YU S S.Paying attention to optimization and combination of the preoperative biomeasurement with intraocular lens power calculation in cataractous eyes[J].Chin J Exp Ophthalmol,2015,33(4):289-293.
汤欣,于莎莎.重视和优选白内障术前生物学测量与人工晶状体屈光度计算的联合方案[J].中华实验眼科杂志,2015,33(4):289-293.
[13] ELDALY M A,MANSOUR K A.Personal A-constant in relation to axial length with various intraocular lenses[J].Indian J Ophthalmol,2014,62(7):788-791.
[14] WANG J K,CHANG S W.Optical biometry intraocular lens power calculation using different formulas in patients with different axial lengths[J].Int J Ophthalmol,2013,6(2):150-154.
[15] KANE J X,VAN HEERDEN A,ATIK A,PETSOGLOU C.Intraocular lens power formula accuracy:Comparison of 7 formulas[J].J Cataract Refract Surg,2016,42(10):1490-1500.
[16] MELLES R B,HOLLADAY J T,CHANG W J.Accuracy of Intraocular Lens Calculation Formulas[J].Ophthalmology,2017:1-10.
[17] HOFFER K J,SAVINI G.IOL power calculation in short and long eyes[J].Asia Pac J Ophthalmol (Phila),2017,6(4):330-331.
[18] CHEN C,XU X,MIAO Y,ZHENG G,SUN Y,XU X.Accuracy of intraocular lens power formulas involving 148 eyes with long axial lengths:A retrospective chart-review study[J].J Ophthalmol,2015:1-10.
[19] ZHANG Y,LIANG X Y,LIU S,LEE J W,BHASKAR S,LAM D S.Accuracy of intraocular lens power calculation formulas for highly myopic eyes[J].J Ophthalmol,2016:1-7.
[20] RAMJI H,MOORE J,MOORE C B,SHAH S.Can the accuracy of multifocal intraocular lens power calculation be improved to make patients spectacle free[J]?Cont Lens Anterior Eye,2016,39(2):160-166.
[21] HOFFMANN P C,HTZ W W.Analysis of biometry and prevalence data for corneal astigmatism in 23,239 eyes[J].J Cataract Refract Surg,2010,36(9):1479-1485.
[22] FERRER-BLASCO T,MONTS-MIC R,PEIXOTO-DE-MATOS S C,GONZLEZ-MIJOME J M,CERVIO A.Prevalence of corneal astigmatism before cataract surgery[J].J Cataract Refract Surg,2009,35:70-75.
[23] SAVINI G,HOFFER K J,DUCOLI P.A new slant on toric intraocular lens power calculation[J].J Refract Surg,2013,29(5):348-354.
[24] SAVINI G,HOFFER K J,CARBONELLI M,DUCOLI P,BARBONI P.Influence of axial length and corneal power on the astigmatic power of toric intraocular lenses[J].J Cataract Refract Surg,2013,39(12):1900-1903.
[25] GOGGIN M,MOORE S,MOORE S,ESTERMAN A.Outcome of toric intraocular lens implantation after adjusting for anterior chamber depth and intraocular lens sphere equivalent power effects[J].Arch Ophthalmol,2011,129(8):998-1003.
[26] FAM H B,LIM K L.Meridional analysis for calculating the expected spherocy- lindrical refraction in eyes with toric intraocular lenses[J].J Cataract Refract Surg,2007,33(12):2072-2076.
[27] KOCH D D,JENKINS R B,WEIKERT M P,YEU E,WANG L.Correcting astigmatism with toric intraocular lenses:Effect of posterior corneal astigmatism[J].J Cataract Refract Surg,2013,39(12):1803-1809.
[28] REITBLAT O,LEVY A,KLEINMANN G,ABULAFIA A,ASSIA E I.Effect of posterior corneal astigmatism on power calculation and alignment of toric intraocular lenses:Comparison of methodologies[J].J Cataract Refract Surg,2016,42(2):217-225.
[29] VISSER N,BERENDSCHOT T T J M,BAUER N J C,JURICH J,KERSTING O,NUIJTS R M M A.Accuracy of toric intraocular lens implantation in cataract and refractive surgery[J].J Cataract Refract Surg,2011,37(8):1394-1402.
[30] HIRNSCHALL N,HOFFMANN P C,DRASCHL P,MAEDEL S,FINDL O.Evaluation of factors influencing the remaining astigmatism after toric intraocular lens implantation[J].J Refract Surg,2014,30(6):394-400.
[31] HOLLADAY J T.Holladay IOL consultant computer program.Houston,TX,Holladay IOL Consultant,1996.
[32] ABULAFIA A,KOCH D D,WANG L,HILL W E,ASSIA E I,FRANCHINA M,et al.New regression formula for toric intraocular lens calculations[J].J Cataract Refract Surg,2016,42(5):663-671.
[33] GOGGIN M,ZAMORA-ALEJO K,ESTERMAN A,VAN ZYL L.Adjustment of anterior corneal astigmatism values to incorporate the likely effect of posterior corneal curvature for toric intraocular lens calculation[J].J Refract Surg,2015,31(2):98-102.
[34] FERREIRA T B,RIBEIRO P,RIBEIRO F J,O’NEILL J G.Comparison of astigmatic prediction errors associated with new calculation methods for toric intraocular lenses[J].J Cataract Refract Surg,2017,43(3):340-347.
[35] PARK D Y,LIM D H,HWANG S,HYUN J,CHUNG T Y.Comparison of astigmatism prediction error taken with the Pentacam measurements,Baylor nomogram,and Barrett formula for toric intraocular lens implantation[J].BMC Ophthalmol,2017,17(1):156.
[36] KOCH D D.The enigmatic cornea and intraocular lens calculations:The LXXIII Edward Jackson Memorial Lecture[J].Am J Ophthalmol,2016,171:xv-xxx.
[37] MORI Y,SHIMIZU K,MINAMI K,KAMIYA K,SHOJI N,MIYATA K.Relationship of corneal asphericity to intraocular lens power calculations after myopic laser in situ keratomileusis[J].J Cataract Refract Surg,2016,42(5):703-709.
[38] KOC M,UZEL M M,AYDEMIR E,YAVRUM F,KOSEKAHYA P,YILMAZBA P.Pterygium size and effect on intraocular lens power calculation[J].J Cataract Refract Surg,2016,42(11):1620-1625.
[39] ABULAFIA A,HILL W E,KOCH D D,WANG L,BARRETT G D.Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia[J].J Cataract Refract Surg,2016,42(3):363-369.
[40] HAMILL E B,WANG L,CHOPRA H K,HILL W,KOCH D D.Intraocular lens power calculations in eyes with previous hyperopic laser in situ keratomileusis or photorefractive keratectomy[J].J Cataract Refract Surg,2017,43(2):189-194.
[41] YAGUCHI Y,NEGISHI K,SAIKI M,TORII H,TSUBOTA K.Comparison of the accuracy of intraocular lens power calculations for cataract surgery in eyes after phototherapeutic keratectomy[J].Jpn J Ophthalmol,2016,60(5):365-372.
[42] REITBLAT O,ASSIA E I,KLEINMANN G,LEVY A,BARRETT G D,ABULAFIA A.Accuracy of predicted refraction with multifocal intraocular lenses using two biometry measurement devices and multiple intraocular lens power calculation formulas[J].Clin Exp Ophthalmol,2015,43(4):328-334.
[43] LADAS J G,SIDDIQUI A A,DEVGAN U,JUN A S.A 3-D “super surface” combining modern intraocular lens formulas to generate a “super formula” and maximize accuracy[J].JAMA Ophthalmol,2015,133(12):1431-1436.
[44] LIN L,CHANG P,XIE J,LI Z,ZHANG H,LU F,et al.Sustained accuracy improvement in intraocular lens power calculation with the application of quality control circle[J].Sci Rep,2017,7(1):14852.

相似文献/References:

[1]甄小妹 马忠旭 刘汝瑜 张娜 张伟 薛庆.全眼球差对人工晶状体眼视觉质量的作用[J].眼科新进展,2012,32(4):000.
[2]王勇 叶应嘉 鲍先议 周龑丽 许荣 彭婷婷 余天.小切口经虹膜缝线固定后房型人工晶状体植入术治疗无晶状体眼[J].眼科新进展,2012,32(5):000.
[3]赵红 陈彬川 王永成 薛晓乐 赵焕.七叶洋地黄双苷滴眼液对不同年龄段人工晶状体眼伪调节力的影响[J].眼科新进展,2012,32(5):000.
[4]曹利群 王桂琴 彭秀军 李娜 卢成戎 贾洪真 石芊.疏水性和肝素修饰亲水性丙烯酸酯人工晶状体的临床应用效果对比[J].眼科新进展,2012,32(5):000.
[5]吴星.年龄相关性白内障患者超声乳化手术前后对比敏感度分析[J].眼科新进展,2012,32(6):000.
[6]徐威.注射器针头囊袋内吸附劈核法在白内障手术中的应用[J].眼科新进展,2012,32(7):000.
[7]刘珣 王欣玲 柏全豪 张劲松 阎启昌.IOLMaster与四种人工晶状体屈光度计算公式的准确性研究[J].眼科新进展,2013,33(2):000.
[8]浦利军.玻璃体切割系统在小瞳孔白内障手术中的应用[J].眼科新进展,2013,33(8):000.
[9]周璐 黄振平.非球面多焦点 IOL 眼的对比敏感度和拟调节力分析[J].眼科新进展,2012,32(1):000.
[10]刘虹 马朋举.AcrySof Toric人工晶状体治疗白内障并矫正角膜散光的临床研究[J].眼科新进展,2012,32(1):000.
[11]马秀艳,周健.高度近视眼人工晶状体度数计算公式的准确性比较[J].眼科新进展,2016,36(9):863.[doi:10.13389/j.cnki.rao.2016.0231]
 MA Xiu-Yan,ZHOU Jian.Accuracy of intraocular lens power calculation formulas in eyes with high axial myopia[J].Recent Advances in Ophthalmology,2016,36(6):863.[doi:10.13389/j.cnki.rao.2016.0231]

备注/Memo

备注/Memo:
国家自然科学基金资助(编号:81470616)
更新日期/Last Update: 2018-07-10