[1]刘春雷,王晶,李彬,等.不同材料及球差人工晶状体眼散射比较分析[J].眼科新进展,2016,36(6):566-568.[doi:10.13389/j.cnki.rao.2016.0150]
 LIU Chun-Lei,WANG Jing,LI Bin,et al.Comparison of ocular scatter between intraocular lenses with different material and spheric aberration[J].Recent Advances in Ophthalmology,2016,36(6):566-568.[doi:10.13389/j.cnki.rao.2016.0150]
点击复制

不同材料及球差人工晶状体眼散射比较分析
分享到:

《眼科新进展》[ISSN:1003-5141/CN:41-1105/R]

卷:
36卷
期数:
2016年6期
页码:
566-568
栏目:
应用研究
出版日期:
2016-06-05

文章信息/Info

Title:
Comparison of ocular scatter between intraocular lenses with different material and spheric aberration
作者:
刘春雷王晶李彬武芹栗映梅贾茹梁霞
250000 山东省济南市,济南市第二人民医院眼科
Author(s):
LIU Chun-Lei WANG Jing LI Bin WU Qin LI Ying-Mei JIA Ru LIANG Xia
Department of Ophthalmology , Jinan Second People ’ s Hospital , Jinan 250000 , Shandong Province , China
关键词:
人工晶状体客观散射指数调制传递函数截止空间频率斯特尔比值像差
Keywords:
intraocular lens optical scattering index modulation transfer function cutoff Strehl Ratio aberration
DOI:
10.13389/j.cnki.rao.2016.0150
文献标志码:
A
摘要:
目的 比较负球差疏水性丙烯酸酯人工晶状体眼和零球差亲水性丙烯酸酯人工晶状体眼术后1个月术眼散射情况。方法 收集我院行超声乳化吸出联合人工晶状体植入术患者60眼,其中30眼植入负球差疏水性丙烯酸酯人工晶状体,定义为TecnisZA9003组;另外30眼植入零球差亲水性丙烯酸酯人工晶状体,定义为SofTecHD组。术后1个月使用欧卡斯测量各组客观散射指数(objectivescatteringindex,OSI)、调制传递函数截止空间频率(modulationtransferfunctioncutoff,MTFcutoff)、斯特尔比值(strehlratio,SR)。使用Pentacam测量各组角膜总高阶像差、球差、水平彗差、垂直彗差,将OSI与其进行相关分析。结果 TecnisZA9003组OSI值为2.020±0.693,MTFcutoff值为21.188±5.965,SR值为0.116±0.039;SofTecHD组OSI值为1.683±0.624,MTFcutoff值为22.797±7.205,SR值为0.131±0.032,组间比较差异均无统计学意义(P=0.053、0.350、0.131)。两组OSI与其角膜总高阶像差、球差、水平彗差、垂直彗差均没有相关性(均为P>0.05)。结论 TecnisZA9003人工晶状体和SofTecHD人工晶状体术后1个月全眼OSI没有差异,且与自身角膜像差没有相关性。
Abstract:
Objective To compare the ocular scatter between hydrophilic acrylic intraocular lens with negative spherical aberration and hydrophobic acrylic intraocular lens with zero spheric aberration at I month after implantation. Methods In this prospective clinical control study ,30 eyes were implanted with hydrophilic acrylic intraocular lenses with negative spherical aberration, defrned as Tecnis ZA9003 group. 30 eyes were implanted with hydrophobic acrylic intraocular lenses with zero spherical aberration, defined as SofTec HD group. The optical scattering index ( OSI) , modulation transfer function cutoff ( MTF cutoff) and Strehl Ratio ( SR) were measured by OQAS TM II at I month after implantation. Comeal total high order aberration, spheric aberration. horizontal and vertical coma were measured by Pentaeam. Their correlation with OSI was analyzed. Results OSI, MTF cutoff and SR in Tecnis ZA9003 group were 2. 020 + 0. 693 .21. 188 + 5. 965 and 0. 116 + 0. 039 , respectively , which in SofTec HD group were 1. 683 +0. 624 .22. 797 +7. 205 and 0. 131 +0. 032 , there was no statistical difference between two groups (P = 0. 053 .0. 350 .0. 131 ) . There was no correlation of OSI with corneal total high order aberration, spheric aberration, horizontal and vertical coma ( all P >0. 05 ). Conclusion There is no difference rn ocular scatter between Tecnis ZA9003 group and SofTec HD group at I month after operation. There is no correlation of OSI with self-corneal aberration.

相似文献/References:

[1]甄小妹 马忠旭 刘汝瑜 张娜 张伟 薛庆.全眼球差对人工晶状体眼视觉质量的作用[J].眼科新进展,2012,32(4):000.
[2]王勇 叶应嘉 鲍先议 周龑丽 许荣 彭婷婷 余天.小切口经虹膜缝线固定后房型人工晶状体植入术治疗无晶状体眼[J].眼科新进展,2012,32(5):000.
[3]赵红 陈彬川 王永成 薛晓乐 赵焕.七叶洋地黄双苷滴眼液对不同年龄段人工晶状体眼伪调节力的影响[J].眼科新进展,2012,32(5):000.
[4]曹利群 王桂琴 彭秀军 李娜 卢成戎 贾洪真 石芊.疏水性和肝素修饰亲水性丙烯酸酯人工晶状体的临床应用效果对比[J].眼科新进展,2012,32(5):000.
[5]吴星.年龄相关性白内障患者超声乳化手术前后对比敏感度分析[J].眼科新进展,2012,32(6):000.
[6]徐威.注射器针头囊袋内吸附劈核法在白内障手术中的应用[J].眼科新进展,2012,32(7):000.
[7]刘珣 王欣玲 柏全豪 张劲松 阎启昌.IOLMaster与四种人工晶状体屈光度计算公式的准确性研究[J].眼科新进展,2013,33(2):000.
[8]浦利军.玻璃体切割系统在小瞳孔白内障手术中的应用[J].眼科新进展,2013,33(8):000.
[9]周璐 黄振平.非球面多焦点 IOL 眼的对比敏感度和拟调节力分析[J].眼科新进展,2012,32(1):000.
[10]刘虹 马朋举.AcrySof Toric人工晶状体治疗白内障并矫正角膜散光的临床研究[J].眼科新进展,2012,32(1):000.

更新日期/Last Update: 2016-06-27