[1]谭亮章,张红,田芳,等. 非球面多焦点散光矫正型人工晶状体植入术后患者的视觉质量[J].眼科新进展,2015,35(9):861-865.[doi:10.13389/j.cnki.rao.2015.0235]
 TAN Liang-Zhang,ZHANG Hong,TIAN Fang,et al. Clinical study of optical quality after aspheric multifocal toric intraocular lens implantation[J].Recent Advances in Ophthalmology,2015,35(9):861-865.[doi:10.13389/j.cnki.rao.2015.0235]
点击复制

 非球面多焦点散光矫正型人工晶状体植入术后患者的视觉质量
分享到:

《眼科新进展》[ISSN:1003-5141/CN:41-1105/R]

卷:
35卷
期数:
2015年9期
页码:
861-865
栏目:
应用研究
出版日期:
2015-09-05

文章信息/Info

Title:
 Clinical study of optical quality after aspheric multifocal toric intraocular lens implantation
作者:
 谭亮章张红田芳穆劲卫
 300384 天津市,天津医科大学眼科医院
Author(s):
 TAN Liang-Zhang ZHANG Hong TIAN Fang MU Jin-Wei
 Tianjin Medical University Eye Hospital, Tianjin 300384 , China
关键词:
 人工晶状体视觉质量对比敏感度脱镜率
Keywords:
 intraocular lens optical quality contrast sensitivity spectacle independence
DOI:
10.13389/j.cnki.rao.2015.0235
文献标志码:
A
摘要:
 目的 评价非球面多焦点散光矫正型人工晶状体植入术后患者的视觉质量。方法 前瞻性对照研究。选取2013年1月至2013年12月在天津医科大学眼科医院行超声乳化白内障吸出术的单纯年龄相关性白内障患者130例(150眼)分为三组,每组50眼。其中,术前规则角膜散光0.5~2.5D患者植入非球面多焦点散光矫正型人工晶状体为试验组(ART组);术前顺规角膜散光<1D,逆规角膜散光<0.75D患者植入非球面多焦点人工晶状体为对照组1(Restor组);术前规则角膜散光1.0~3.0D患者植入非球面散光矫正型人工晶状体为对照组2(Toric组)。术后1d、1周、1个月、3个月用OQAS视觉质量分析仪检查三组患者的OQAS参数、对比敏感度、裸眼远视力、最佳矫正远视力,并进行脱镜率和患者满意度调查,绘制三组患者的离焦曲线;检查ART组和Restor组的最佳近视力、60cm中距离视力;检查ART组和Toric组的轴位旋转度。结果 三组裸眼远视力及最佳矫正远视力差异无统计学意义(F=0.661,P=0.518;F=0.013,P=0.987);ART组与Restor组中距离视力及最佳近视力差异均无统计学意义(t=-0.796,P=0.428;t=-0.885,P=0.378);OQAS参数检查发现:三组的客观散射指数、调制传递函数截止频率值、OV100%、OV20%、OV9%差异均无统计学意义(均为P>0.05);三组的斯特列尔比值、对比敏感度结果比较,差异均有统计学意义(均为P<0.05),其中ART组与Restor组差异均无统计学意义(均为P>0.05);术后3个月轴位旋转度,ART组与Toric组差异无统计学意义(t=1.036,P=0.303);ART组与Restor组脱镜率分别为90%和88%,高于Tor-ic组的12%,三组均未发现明显视觉干扰现象。结论 非球面多焦点散光矫正型人工晶状体在有效矫正角膜散光的基础上,可以提供一个良好的全程视力,提高了患者脱镜率。
Abstract:
 Objective To observe the optical quality after aspheric multifocal toric intraocular lens ( IOL) implantation. Methods It was a case-control study. One hundred and fifty eyes of 130 patients underwent phacoemulsification in Tianjin Medical University Eye Hospital from January 2013 to December 2013 were enrolled and divided into three groups , one was of ART IOL with 0. 5 - 2. 5 D corneal regular astigmatism , one was of Restor IOL with below l. 0 D astigmatism with the rule or below 0. 75D astigmatism against the rule , the other was of Toric IOL with l. 0 - 3. 0 D corneal regular astigmatism. The main measurements included optical scattering index ( OSI) , modulation transfer function cutoff ( MTF cutoff) . Strehl ratio , optical quality analysis system values ( OV) .contrast sensitivity , uncorrected distance visual acuity ( UDVA ) . corrected distance visual acuity ( CDVA) , distance corrected near visual acuity ,intermediate visual acuity (60 cm) at postoperative I day,l week,l month.3 months. IOL rotation,defocus measurement and spectacle independence survey were also detected after surgery at postoperative I day , I week, I month , 3 months. Results There was no statistically significant difference in both UDVA and CDVA among groups ( F = 0. 661 ,P = 0. 5 18 ;F = 0. 013 .P = 0. 987 ) . There was no statistically significant difference in the near vision and intermediate visual acuity between ART group and Restor group ( t = - 0. 796 ,P = 0. 428 ; t = - 0. 885 , P = 0. 378 ) . No statistically sigruficant difference was noted among three groups in OSI,MTF cutoff , OVIOO% , OV20% .OVg% ( all P > 0. 05 ) . There were significant differences in Strehl ratio and contrast sensitivity among three groups ( all P < 0. 05 ) .but no statistical sigruficant difference was noted between ART group and Restor group ( all P > 0. 05 ) . There was no significant difference in IOL rotation ART group and Toric group ( t = 1. 036 .P = 0. 303 ) . The percentages of spectacle independence were 90% and 88% in ART group and Restor group , respectively. No significant visual interference problems was noted among three groups. Conclusion On the basis of the effective correction corneal astigmatism,the aspheric multifocal toric IOL implantation can provide a good vision, improve the rate of spectacle independence.

相似文献/References:

[1]甄小妹 马忠旭 刘汝瑜 张娜 张伟 薛庆.全眼球差对人工晶状体眼视觉质量的作用[J].眼科新进展,2012,32(4):000.
[2]王勇 叶应嘉 鲍先议 周龑丽 许荣 彭婷婷 余天.小切口经虹膜缝线固定后房型人工晶状体植入术治疗无晶状体眼[J].眼科新进展,2012,32(5):000.
[3]赵红 陈彬川 王永成 薛晓乐 赵焕.七叶洋地黄双苷滴眼液对不同年龄段人工晶状体眼伪调节力的影响[J].眼科新进展,2012,32(5):000.
[4]曹利群 王桂琴 彭秀军 李娜 卢成戎 贾洪真 石芊.疏水性和肝素修饰亲水性丙烯酸酯人工晶状体的临床应用效果对比[J].眼科新进展,2012,32(5):000.
[5]吴星.年龄相关性白内障患者超声乳化手术前后对比敏感度分析[J].眼科新进展,2012,32(6):000.
[6]徐威.注射器针头囊袋内吸附劈核法在白内障手术中的应用[J].眼科新进展,2012,32(7):000.
[7]刘珣 王欣玲 柏全豪 张劲松 阎启昌.IOLMaster与四种人工晶状体屈光度计算公式的准确性研究[J].眼科新进展,2013,33(2):000.
[8]浦利军.玻璃体切割系统在小瞳孔白内障手术中的应用[J].眼科新进展,2013,33(8):000.
[9]周璐 黄振平.非球面多焦点 IOL 眼的对比敏感度和拟调节力分析[J].眼科新进展,2012,32(1):000.
[10]刘虹 马朋举.AcrySof Toric人工晶状体治疗白内障并矫正角膜散光的临床研究[J].眼科新进展,2012,32(1):000.
[11]孙康 毕伍牧 杜云 苏颍丹 钟志伟. 光致变色蓝光滤过型人工晶状体对人眼色觉的影响[J].眼科新进展,2014,34(1):061.
[12]毕伍牧 孙康 杜云 钟志伟. 光致变色蓝光滤过型IOL和蓝光滤过型黄色IOL对术眼对比敏感度影响的对比研究[J].眼科新进展,2014,34(2):175.
[13]张蕾,谭荣强,周家承,等. 梅毒螺旋体感染患者白内障手术效果观察[J].眼科新进展,2014,34(7):684.[doi:10.13389/j.cnki.rao.2014.0188]
[14]李保江,宋徽,高晓唯,等. 无巩膜瓣经巩膜缝线固定后房折叠型人工晶状体植入术的临床研究[J].眼科新进展,2014,34(9):852.[doi:10.13389/j.cnki.rao.2014.0235]
[15]申颖,陆晓和. 内窥镜直视下房角分离术联合超声乳化人工晶状体植入术治疗原发性闭角型青光眼[J].眼科新进展,2015,35(4):343.[doi:10.13389/j.cnki.rao.2015.0092]
 SHEN Ying,LU Xiao-He. Endoscopic directed chamber angle separation combined with phacoemulsification and IOL implantation for primary angle-closure glaucoma[J].Recent Advances in Ophthalmology,2015,35(9):343.[doi:10.13389/j.cnki.rao.2015.0092]

更新日期/Last Update: 2015-08-31