[1]凌玲,陈敬旺,姚玲,等.角膜基质透镜散光标记器在角膜基质透镜植入术矫正远视及散光中的应用[J].眼科新进展,2021,41(9):861-864.[doi:10.13389/j.cnki.rao.2021.0180]
 LING Ling,CHEN Jingwang,YAO Ling,et al.Application of corneal stromal lens astigmatism marker in corneal stroma lens implantation for correcting hyperopia and astigmatism[J].Recent Advances in Ophthalmology,2021,41(9):861-864.[doi:10.13389/j.cnki.rao.2021.0180]
点击复制

角膜基质透镜散光标记器在角膜基质透镜植入术矫正远视及散光中的应用/HTML
分享到:

《眼科新进展》[ISSN:1003-5141/CN:41-1105/R]

卷:
41卷
期数:
2021年9期
页码:
861-864
栏目:
应用研究
出版日期:
2021-09-05

文章信息/Info

Title:
Application of corneal stromal lens astigmatism marker in corneal stroma lens implantation for correcting hyperopia and astigmatism
作者:
凌玲陈敬旺姚玲柯慧敏周文天
330006 江西省南昌市,南昌大学附属眼科医院
Author(s):
LING LingCHEN JingwangYAO LingKE HuiminZHOU Wentian
The Affiliated Eye Hospital of Nanchang University, Nanchang 330006, Jiangxi Province, China
关键词:
角膜基质透镜散光标记器飞秒激光辅助的瓣下角膜基质透镜植入术小切口飞秒激光角膜基质透镜取出术远视散光
Keywords:
corneal stromal lens astigmatism marker femtosecond laser assisted subvalvular corneal stromal lens implantation small incision lenticular extraction hyperopia astigmatism
分类号:
R772
DOI:
10.13389/j.cnki.rao.2021.0180
文献标志码:
A
摘要:
目的 探讨角膜基质透镜散光标记器(简称散光标记器)在角膜基质透镜植入术矫正远视及散光中的应用。方法 前瞻性病例研究。选取2019年12月至2020年12月在南昌大学附属眼科医院屈光科就诊的满足手术要求的远视及散光患者6例6眼,年龄20~36 (27.50±6.72)岁,所有患者均行飞秒激光辅助的瓣下角膜基质透镜植入术(FS-LIKE)。供体角膜取自同期行飞秒激光小切口角膜基质透镜取出术(SMILE)的近视患者,术中利用散光标记器标记角膜基质透镜散光轴位并植入到事先标记好轴位的植床以矫正远视和散光。术后随访6个月,观察所有术眼的裸眼视力(UCVA)、裸眼近视力(UNVA)、最佳矫正视力(BCVA)、等效球镜度、手术安全性及有效性。采用标准矢量分析法对手术前后散光相关指标进行评估。结果 所有术眼术后1 d、1周、1个月、3个月、6个月 UCVA、UNVA较术前均明显提高(F=5.503、2.968,P=0.002、0.031),术后不同时间点UCVA、UNVA两两比较差异均无统计学意义(均为P>0.05)。术后安全性指数及有效性指数分别为1.17±0.26、0.96±0.25。所有术眼术后BCVA较术前均未见丢失, 4眼无变化,2眼提高2行。所有患者术后6个月手术矫正散光量及角度误差分别为(2.24±0.98)D、(5.33±5.79)°。结论 散光标记器在FS-LIKE术中能有效标记散光轴位和受体角膜定位,能够有效安全地矫正患者术前远视及散光,为远视散光患者提供了新的、有效的一体式手术方式。
Abstract:
Objective To explore the clinical application of corneal stromal lens astigmatism marker (astigmatism marker in the following text) in the correction of hyperopia and astigmatism after corneal stroma lens implantation.Methods It was a prospective study involving 6 patients (6 eyes) with hyperopia and astigmatism who met the surgical requirements in the Department of Ophthalmology, Affiliated Eye Hospital of Nanchang University from December 2019 to December 2020. Their age was 20-36 (27.50±6.72) years. All patients were treated with femtosecond laser-assisted subvalvular corneal stromal lens implantation (FS-LIKE). The donor cornea was taken from myopic patients who underwent small incision lenticular extraction (SMILE) during the same period. During the operation, astigmatism markers were used to mark the astigmatism axis of corneal stroma lens and implanted into the previously marked implant bed to correct hyperopia and astigmatism. The uncorrected visual acuity (UCVA), near visual acuity (UNVA), best corrected visual acuity (BCVA), equivalent spherical diopter, surgical safety and effectiveness were observed during the 6 months of postoperative follow-up. The astigmatism-related indexes before and after operation were evaluated by the standard vector analysis.Results Patient’s UCVA and UNVA levels at 1 day, 1 week, 1 month, 3 months and 6 months postoperatively were significantly higher than preoperative levels (F=5.503 and 2.968, P=0.002 and 0.031, respectively). There were no significant differences in UCVA and UNVA at each time point after operation (all P>0.05). The postoperative safety index and effectiveness index were 1.17±0.26 and 0.96±0.25, respectively. There was no loss of BCVA in all patients postoperatively. In addition, 4 eyes did not have the improvement of UNVA, and 2 eyes increased by 2 lines. Six months after operation, the amount of astigmatism corrected by surgery for all patients and the angle error were (2.24 ±0.98) D and (5.33 ±5.79)°, respectively.Conclusion The astigmatism marker can effectively mark the axis of astigmatism and the location of the recipient cornea during the procedure of FS-LIKE. Moreover, it can effectively and safely correct preoperative hyperopia and astigmatism. Our findings provide a new and effective choice of integrated operation for patients with hyperopic astigmatism.

参考文献/References:

[1] GUPTA P C,CATY J T.Astigmatism evaluation prior to cataract surgery [J].Curr Opin Ophthalmol,2018,29(1):9-13.
[2] HARB E N,WILDSOET C F.Origins of refractive errors:environmental and genetic factors [J].Annu Rev Vis Sci,2019,5:47-72.
[3] CHEN K,HU Z,ZHOU J,YU T,XU J,BAI J,et al.Vector analysis of the effects of FS-LASIK and Toric ICL for moderate to high astigmatism correction[J].J Ophthalmol,2018,2018:6952710.
[4] TOY B C,MANCHE E E.Vector analysis of 1-year astigmatic outcomes from a randomized fellow eye comparison of photorefractive keratectomy using 2 excimer laser platforms [J].Eye Contact Lens,2018,44 (Suppl 1):S71-S76.
[5] MASTROPASQUA L,NUBILE M.Corneal thickening and central flattening induced by femtosecond laser hyperopic-shaped intrastromal lenticule implantation [J].Int Ophthalmol,2017,37(4):893-904.
[6] 周跃华,张晶,郑燕,刘倩,魏文斌,王宁利.同种异体角膜基质透镜植入术矫治远视的早期临床疗效 [J].中华眼科杂志,2015,51(9):683-688.
ZHOU Y H,ZHAGN J,ZHENG Y,LIU Q,WEI W B,WANG N L.The early clinical efficacy of allogeneic corneal lens inlays in correction of hyperopia [J].Chin J Ophthalmol,2015,51(9):683-688.
[7] MOSHIRFAR M,HOPPING G C,SOMANI A N,VAIDYANATHAN U,LIU H,BARNES J R,et al.Human allograft refractive lenticular implantation for high hyperopic correction [J].J Cataract Refract Surg,2020,46(2):305-311.
[8] 晏利,凌玲,喻理,徐婉欣,查琴,谢丽萍,等.飞秒激光辅助的角膜基质透镜植入术矫正远视的早期临床观察 [J].眼科新进展,2020,40(8):751-754,760.
YAN L,LING L,YU L,XU W X,ZHA Q,XIE L P,et al.Early clinical study of femtosecond laser-assisted intrastromal lenticular implantation in correcting hyperopia [J].Rec Adv Ophthalmol,2020,40(8):751-754,760.
[9] EYDELMAN M B,DRUM B,HOLLADAY J,HILMANTEL G,KEZIRIAN G,DURRIE D,et al.Standardized analyses of correction of astigmatism by laser systems that reshape the cornea [J].J Refract Surg,2006,22(1):81-95.
[10] XI L,ZHANG C,HE Y.Clinical outcomes of transepithelial photorefractive keratectomy to treat low to moderate myopic astigmatism [J].BMC Ophthalmol,2018,18(1):115.
[11] SETTAS G,SETTAS C,MINOS E,YEUNG I Y.Photorefractive keratectomy (PRK) versus laser assisted in situ keratomileusis (LASIK) for hyperopia correction [J].Cochrane Database Syst Rev,2012(6):D7112.
[12] MOSHIRFAR M,SHAH T J,MASUD M,FANNING T,LINN S H,RONQUILLO Y,et al.A Modified small-incision lenticule intrastromal keratoplasty (sLIKE) for the correction of high hyperopia:a description of a new surgical technique and comparison to lenticule intrastromal keratoplasty (LIKE) [J].Med Hypothesis Discov Innov Ophthalmol,2018,7(2):48-56.
[13] PRADHAN K R,REINSTEIN D Z,CARP G I,ARCHER T J,GOBBE M,GURUNG R.Femtosecond laser-assisted keyhole endokeratophakia:correction of hyperopia by implantation of an allogeneic lenticule obtained by SMILE from a myopic donor [J].J Refract Surg,2013,29(11):777-782.
[14] ZHAO J,SHANG J,NIU L,XU H,YANG D,ZHAO Y,et al.Two-year outcome of an eye that underwent hyperopic LASIK following inadvertent myopic SMILE lenticule in situ implantation [J].BMC Ophthalmol,2019,19(1):176.
[15] GANESH S,BRAR S,RAO P A.Cryopreservation of extracted corneal lenticules after small incision lenticule extraction for potential use in human subjects [J].Cornea,2014,33(12):1355-1362.

备注/Memo

备注/Memo:
江西省重点研发计划项目(编号:20171BBG70098);江西省卫生健康委科技计划项目(编号:20201074)
更新日期/Last Update: 2021-09-05